System Maintenance
63
8. Power on the replacement SV Router. When powered on the new SV Router will download
the SAN database from the existing router. However, it will not download its zone
configuration. You must do this manually.
9. Using the
slicview
command, determine and record the new SV Router’s initiator
number.
10. Using the
sanconfig import
command, import zone configuration to the replacement
SV Router.
Example
sanconfig import -d SAN1r0 -e /svengine/SANconf/T3SAN.san -r i3 -j
i2
Usage
-r i3
new replacement router
-j i2
old failed router
Note: The initiator numbers I00001 and I00002 can be written without zeroes (I1, I2, etc.)
11. Power off the SV Router, and connect data server FC HBAs to the new SV Router.
12. Power on SV Router.
13. Using the
slicview view
command, view the router zone configuration information to
ensure that all zones were assigned to their designated HBAs.
14. Using the
sadapter view
command, ensure the HBA sees its assigned drives.
Example:
sadapter view -d SAN1r0 -r I2
15. Using the
sanconfig read
command, save SAN configuration in file.
Example
sanconfig read -d SAN1r0 -e /svengine/SANconf/T3SAN.san
16. Replacement is complete.
17. If T3 configuration, perform T3 failback.
18. If you are running Vertias Volume Manager with DMP, type
vxdctl enable
to enable
Veritas path. This should be done on each data server.
Содержание FC-FC3
Страница 6: ...vi...
Страница 10: ...SV Router FC FC 3 Installation and User Guide Sun Release x Glossary 77 Index 87...
Страница 12: ...SV Router FC FC 3 Installation and User Guide Sun Release xii...
Страница 62: ...SV Router FC FC 3 Installation and User Guide Sun Release 48...
Страница 70: ...SV Router FC FC 3 Installation and User Guide Sun Release 56...
Страница 80: ...SV Router FC FC 3 Installation and User Guide Sun Release 66...
Страница 88: ...SV Router FC FC 3 Installation and User Guide Sun Release 74...
Страница 100: ...86 SV Router FC FC 3 Installation and User Guide Sun Release...