Summary of Contents for 201840-xxx

Page 1: ...Manual And Troubleshooting Guide February 24 2009 Rev B Moog Components Group Springfield Operations 750 West Sproul Road Springfield PA 19064 E Mail mcg moog com URL www moog com components Tel 610 328 4000 Fax 610 605 6216 24 7 Technical Customer Support Hotline 610 605 6101 ...

Page 2: ...ETHERNET BOARD P N 201840 XXX 3 1 1 VME DUAL PORT GIGABIT ETHERNET BOARD REVISION HISTORY 3 1 2 VME DUAL PORT GIGABIT ETHERNET BOARD DASH NUMBER DEFINITIONS 3 1 3 VME DUAL PORT GIGABIT ETHERNET BOARD OPERATION 4 1 3 1 Gigabit Ethernet Board Indicators and Controls 4 1 3 2 VME Dual Port Gigabit Ethernet Board Specifications 7 1 3 3 Gigabit Ethernet board Dimensions 7 1 3 4 Gigabit Ethernet board Po...

Page 3: ...hernet devices This board will not support 10 or 100 Mbps Ethernet The Gigabit Ethernet board will operate as either a subsea or surface interface board so it can be used as a spare for either location The optical modules used on the board are inherently bi directional and care must be taken to ensure the correct optical port either TX or RX is connected depending on the board configuration and sy...

Page 4: ...flash ON then OFF to indicate that the GBE chips U5 and J9 are starting Even if the two boards are optically connected neither LED on RJ 45 connectors J4 and J7 will light until a valid GBE signal is present at BOTH ends of the fiber optic link Once valid GBE signals are seen at both ends of the link then the LEDs on J4 and J7 will activate 1 3 1 Gigabit Ethernet Board Indicators and Controls LEDS...

Page 5: ...e D4 Green Located on the upper front edge of the board labeled FIBER 1 provides an indication that the transceiver module has detected the presence of an input signal on the fiber link When ON indicates that this board has a good level of received optical power from the remote unit A NOTE THIS LED WILL BE ON WHETHER ETHERNET DATA IS PRESENT OR NOT D6 Green Located on the upper front edge of the b...

Page 6: ...programming do not use J6 SFP optical module for Link 2 J7 RJ 45 GBE Ethernet connector for Link 2 J8 5 pin header for U9 programming do not use J9 3 pin Phoenix connector for RS 485 PMON2 Diagnostics J9 3 pin Phoenix Connector for Diagnostics o 1 RT Left o o o o o o o o Right J4 Gigabit Ethernet RJ 45 Connector Pin 8 7 6 5 4 3 2 1 Pin 1000Mbps 1 A 2 A 3 B 4 C 5 C 6 B 7 D 8 D Left o o o o o o o o ...

Page 7: ...inted circuit board PCB 3 937 inches x 6 299 inches 100mm x 160 mm 1 3 4 Gigabit Ethernet board Power Requirements The Gigabit Ethernet board utilizes approximately 2 5 Watts of power 5 0VDC input approximately 500mA 1 3 5 Power Section Testing NOTE The connectors and components on the bottom of the Gigabit Ethernet board have pins that are connected to internal supply voltages and ground If these...

Page 8: ...es Verify that the Ethernet devices at both ends of the link are powered up Verify that both of the dual LEDS at J4 and J7 are lit to confirm Ethernet activity at the RJ 45 connector Attempt to PING from one device to the other If the channel is still not operating correctly first check the field wiring If the wiring appears correct then first replace the subsea Gigabit Ethernet board with a spare...