System Maintenance
65
15. Using the
sanconfig read
command, save the SAN configuration to file.
Example
sanconfig read -d SAN1r0 -e /svengine/SANconf/T3SAN.san
16. Connect the data server FC HBAs to both replacement routers.
17. Using the
sadapter view
command, ensure the HBA sees both SV Routers.
Example:
sadapter view -d SAN1r0 -r I1
sadapter view -d SAN1r0 -r I2
18. Replacement is complete.
19. Using the
sanconfig read
command, save the SAN configuration to file.
20. Perform T3 failback if necessary.
21. If you are running Vertias Volume Manager with DMP, type
vxdctl enable