15
•
Ceramic plates (5 pcs.)
•
Clearing brush
•
Binding material
•
Distance clamp (2 pcs.)
•
Screws ST 4,8 x 13 (2 pcs.) for distance clamp gripping
•
Bushing PG 13,5 (2 pcs.)
•
Bushing PG 11 (2 pcs.)
•
Stud bolt M10 x 30 (4 pcs), washers 10,5 (4 pcs) and nuts M10 (4 pcs) for gripping of fuel feeder set to
the pedestal
•
Hexagon screws M8 x 20 (4 pcs.), washers 8,4 (4 pcs.) and nuts M8 (4 pcs) for gripping of fuel reservoir
to the fuel feeder
•
Screws M6 x 16 (4 pcs), washers 6,4 (4 pcs) and nuts M6 (4 pcs) for attaching the service board to the
fuel tank
•
Inlet and outlet valve 1/2 "
•
Cast iron grate (large diameter)
•
Silicon sealant – a tube 310 ml
•
Thermostatic valve BVTS (Danfoss) or TS 130 (Honeywell) or STS 20 (Watts)
•
Boiler sensor QAZ 36.526/109
•
Sensor against fuel fire penetration QAZ 36.526/109
•
Outside sensor QAC 34/101 (required for equitherm control of the pump and mixing heating circuit)
•
Thermostatic valve (filling valve) - series VTC312 (external thread) made by ESBE (minimum
temperature of return water is 45
o
C) (ord. code: 5100 15 00)
•
Sticker - LED for the safety thermostat signalization
•
Boiler operation and installation manual, a guarantee list is its part
•
List of contract service organization
•
Thermostatic valve TS 130 (STS 20) (1 pc)
Obligatory accessories for mixing heating circuit (not included in the delivery):
•
Heating branch sensor QAD 36/101 (Siemens)
•
Three-way mixing valve VBI31.20 with drive SQK34.00 (Siemens)
•
Water heater thermostat type: 7K1.6R326.00A (capillary length: 1000 mm, range: 0 - 60 oC) (in case
boiler will be used for HW heating)
Obligatory accessories for pump heating circuit (not included in the delivery):
•
Hot water sensor QAZ36.526/109 (in case boiler will be used for HW heating) (Siemens)
•
Three-way valve V4044F (in case boiler will be used for HW heating) (Honeywell). – in this case only the
phase, working and protective conductors will be connected. Note: also V4044C valve can be used.
Obligatory accessories (not included in the delivery):
•
Safety valve (1 pc) according to the maximum boiler operating overpressure (see tab. no. 1)
Optional:
•
HMI (ACX84.910/ALG) service unit for Saphir regulator operation – Siemens
•
Circuit pump UPS 25-40
•
Water heater (see the VIADRUS division offer)
The optional boiler equipment is not included in the boiler standard price.