P 131
HW time schedule reset
By this parameter activation the time regime returns to the manufacturer’s setting
Value 1 – activation
P 140
Feeder runtime
[s]
Feeder runtime in automatic regime
P 150
Feeder X1 lignite
[%]
It regards the percentage value of output.
The value 0 represents the min. output and the feeder standstill time of parameter 151 is assigned to
this value
Note: This parameter cannot be changed
P 151
Feeder Y1 lignite
[s]
Setting the feeder standstill time for HU fuel relating to 0% output
P 152
Feeder X2 lignite
[%]
It regards the percentage value of output.
The value 33 represents the 33% output and the feeder standstill time of parameter 153 is assigned to
this value. Note: This parameter cannot be changed
P 153
Feeder Y2 lignite (HU)
[s]
Setting the feeder standstill time for HU fuel relating to 33% output
P 154
Feeder X3 lignite
[%]
It regards the percentage value of output.
The value 33 represents the 66% output and the feeder standstill time of parameter 155 is assigned to
this value Note: This parameter cannot be changed
P 155
Feeder Y3 lignite
[s]
Setting the feeder standstill time for HU fuel relating to 66% output
P 156
Feeder X4 lignite
[%]
It regards the percentage value of output.
The value 33 represents the 100 % output and the feeder standstill time of parameter 157 is assigned
to this value. Note: This parameter cannot be changed
P 157
Feeder Y4 lignite
[s]
Setting the feeder standstill time for HU fuel relating to 100% output
P 158
Feeder runtime in the attenuation – lignite
[s]
Setting the feeder runtime in the attenuation regime for HU fuel
P 159
Standstill time(delay) of feeder in the attenuation – lignite
[min.]
Standstill of feed screw in the attenuation regime for HU fuel
P 160
Ventilator X1 lignite
[%]
It regards the percentage value of ventilator output.
The value 0 represents min. ventilator output and the actual ventilator output of parameter 161 is
assigned to this value. Note: This parameter cannot be changed
P 161
Ventilator Y1 lignite
[%]
Setting the actual ventilator output for HU fuel relating to 0% ventilator output
P 162
Ventilator X2 lignite
[%]
It regards the percentage value of ventilator output
The value 33 represents 33% ventilator output and the actual ventilator output of parameter 163 is
assigned to this value. Note: This parameter cannot be changed
P 163
Ventilator Y2 lignite
[%]
Setting the actual ventilator output for HU fuel relating to 33% ventilator output
P 164
Ventilator X3 lignite
[%]
It regards the percentage value of ventilator output
The value 66 represents 66% ventilator output and the actual ventilator output of parameter 165 is
assigned to this value. Note: This parameter cannot be changed
P 165
Ventilator Y3 lignite
[%]
Setting the actual ventilator output for HU fuel relating to 66% ventilator output
P 166
Ventilator X4 lignite
[%]
It regards the percentage value of ventilator output
The value 100 represents 100% ventilator output and the actual ventilator output of parameter 167 is
assigned to this value. Note: This parameter cannot be changed