42
Parameter
Description
Units
Set by the
manufacturer
Range
Resolution
P 225
Ventilator Y3 pellets
[%]
24/37
14…40/25…50
1
P 226
Ventilator X4 pellets
[%]
100
100
0
P 227
Ventilator Y4 pellets
[%]
32/41
20…45/25…60
1
P 228
Ventilator slowing-down in the attenuation
regime– pellets
[s]
3
1 … 60
1
P 229
Ventilator output in the attenuation – pellets
[%]
100
50 … 100
1
P 231
Superior control ON / OFF
0
0 … 1
1
P 232
Outside sensor deactivation
1
0 … 1
1
P 233
Diagnostics HC
-
-
-
P 234
Diagnostics boiler
-
-
-
P 235
Restoration of manufacturer’s setting
0
0 … 1
1
P 238
Year
-
2000 - 2050
1
P 239
Date
-
01.01. – 31. 12.
Day
P 240
Time
-
00:00 – 23:59
Minute
6.2.1 Description of SAPHIR regulator parameters
P 1
Current outside temperature
[
o
C]
Current outside temperature displayed. The lowest displayed value of outside temperature is -20
o
C.
P 2
Current boiler temperature
[
o
C]
Current boiler outlet temperature displayed.
P 3
Current heating circuit temperature
[
o
C]
Current heating circuit temperature displayed
P 4
Desired heating circuit temperature
[
o
C]
Current desired heating circuit temperature displayed
P 5
Current temperature HW
[
o
C]
Current HW temperature displayed
P 6
Desired boiler temperature in case of HW heating
[
o
C]
Current desired boiler outlet temperature in case of water demand on heating displayed
P 7
Current warm water thermostat status
[
o
C]
Current HW thermostat status displayed
P 8
Current feeder temperature
[
o
C]
Current feeder temperature displayed
P 9
Current space temperature
[
o
C]
Current space temperature displayed
P 10
Current position of three-way mixing valve
[%]
Current position of three-way mixing valve displayed
P 11
Desired boiler temperature
[
o
C]
Current desired boiler outlet temperature displayed
P 12
Current ventilator output
[%]
Current ventilator output displayed
P 15
Faults
Current boiler fault displayed. Description of individual faults see tab. no. 8.
In case 0 is on the line no fault is detected.
P 19
Parallel shift in the heating curve
[
o
C]
By increasing the value the parallel shift in heating curve will occur (parameter P 21) thus the desired
heating water temperature will be increased
P 20
Fuel type
Selection of required fuel (value 1, 2, 3)
1
– lignite
2
– hard coal
3
– wood pellets