39
Parameter
Description
Units
Set by the
manufacturer
Range
Resolution
P 169
Ventilator output in the attenuation – lignite
[%]
50
10 … 100
1
P 170
Feeder X1 hard coal
[%]
0
0
0
P 171
Feeder Y1 hard coal (3 sect./4 sect.)
[s]
120/105
70..150/60..150
1
P 172
Feeder X2 hard coal
[%]
33
33
0
P 173
Feeder Y2 hard coal (3 sect./4 sect.)
[s]
85/58
50..120/40..110
1
P 174
Feeder X3 hard coal
[%]
66
66
0
P 175
Feeder Y3 hard coal (3 sect./4 sect.)
[s]
58/41
40..110/30..80
1
P 176
Feeder X4 hard coal
[%]
100
100
0
P 177
Feeder Y4 hard coal (3 sect./4 sect.)
[s]
42/30
30..80/20..80
1
P 178
Feeder runtime in the attenuation – hard coal
[s]
10
3 … 20
1
P 179
Standstill time(delay) feeder in the attenuation –
hard coal
[min.]
40
10 … 240
1
P 200
Ventilator X1 hard coal
[%]
0
0
0
P 201
Ventilator Y1 hard coal (3 sect./4 sect.)
[%]
16/17
5..70/5..70
1
P 202
Ventilator X2 hard coal
[%]
33
33
0
P 203
Ventilator Y2 hard coal (3 sect./4 sect.)
[%]
22/23
10..80/10..80
1
P 204
Ventilator X3 hard coal
[%]
66
66
0
P 205
Ventilator Y3 hard coal (3 sect./4 sect.)
[%]
32/39
15..80/15..80
1
P 206
Ventilator X4 hard coal
[%]
100
100
0
P 207
Ventilator Y4 hard coal (3 sect./4 sect.)
[%]
44/52
20..80/20..80
1
P 208
Ventilator slowing-down in the attenuation
regime– hard coal
[s]
90
5 … 200
1
P 209
Ventilator output in the attenuation – hard coal
[%]
50
10 … 100
1
P 210
Feeder X1 pellets
[%]
0
0
0
P 211
Feeder Y1 pellets (3 sect./4 sect.)
[s]
32/56
22…42/46...66
1
P 212
Feeder X2 pellets
[%]
33
33
0
P 213
Feeder Y2 pellets (3 sect./4 sect.)
[s]
22/29
12…32/19…39
1
P 214
Feeder X3 pellets
[%]
66
66
0
P 215
Feeder Y3 pellets (3 sect./4 sect.)
[s]
16/17
6…30
1
P 216
Feeder X4 pellets
[%]
100
100
0
P 217
Feeder Y4 pellets (3 sect./4 sect.)
[s]
12/13
5…25
1
P 218
Feeder runtime in the attenuation – pellets
[s]
15
13 … 20
1
P 219
Standstill time(delay) feeder in the attenuation –
pellets
[min.]
10
5 … 15
1
P 220
Ventilator X1 pellets
[%]
0
0
0
P 221
Ventilator Y1 pellets (3 sect./4 sect.)
[%]
7/6
4…15
1
P 222
Ventilator X2 pellets
[%]
33
33
0
P 223
Ventilator Y2 pellets (3 sect./4 sect.)
[%]
15/22
10…25/12…35
1
P 224
Ventilator X3 pellets
[%]
66
66
0
P 225
Ventilator Y3 pellets (3 sect./4 sect.)
[%]
24/37
14…40/25…50
1
P 226
Ventilator X4 pellets
[%]
100
100
0
P 227
Ventilator Y4 pellets (3 sect./4 sect.)
[%]
32/41
20…45/25…60
1
P 228
Ventilator slowing-down in the attenuation
regime– pellets
[s]
3
1 … 60
1
P 229
Ventilator output in the attenuation – pellets
[%]
100
50 … 100
1
P 232
Outside sensor deactivation
0
0 … 1
1
P 233
Diagnostics HC
-
-
-
P 234
Diagnostics boiler
-
-
-
P 235
Restoration of manufacturer’s setting
0
0 … 1
1
P 238
Year
-
2000 - 2050
1
P 239
Date
-
01.01. – 31. 12.
Day
P 240
Time
-
00:00 – 23:59
Minute