manualshive.com logo in svg
background image

Supplementary installation, operating and maintenance instructions  English 

Explosion-proof three-phase asynchronous motors with squirrel-cage rotor for high voltage 

 
 

 
815001 Edition 09.2020                                                                                                                                                                                                                                                                                                                                                                                                         
 

20 

Annex 1 

 

VEM motors GmbH · Postfach 101252 · 38842 Wernigerode

 

 

 

ERKLÄRUNG FÜR DEN EINBAU EINER UNVOLLSTÄNDIGEN MASCHINE

 

nach Maschinenrichtlinie 2006/42/EG, Anhang II Teil 1B 

DECLARATION OF INCORPORATION OF PARTLY COMPLETED MACHINERY

 

acc. to Machinery Directive 2006/42/EC, Annex II Part 1B 

 

Hiermit erklärt der Hersteller: 
The manufacturer hereby declares: 

VEM motors GmbH 
Carl-Friedrich-Gauß-Strasse 1 
38855 Wernigerode 
Germany 

der unvollständigen Maschine: 
for the partly completed machinery: 
  

 

 

Hochspannungsmotor 

 

 

 

Typ 

W52R 400

   

 

Serien-

Nr.  ……………. 

  

 

 

High voltage motor 

 

 

 

Type 

W52R 400

 

 

Serial-No. ................ 

 

die Anwendung und Einhaltung folgender grundlegender Anforderungen nach Anhang I: 
the application and fulfilment of the following essential requirements acc. to Annex I: 
 
  

 

 

1.1.2, 1.1.3, 1.1.5, 1.2.6, 1.3.1, 1.3.2, 1.3.3, 1.3.4, 1.3.7, 1.3.8.1, 

  

 

 

1.5.1, 1.5.2, 1.5.4, 1.5.5, 1.5.6, 1.5.7, 1.5.8, 1.5.9, 1.5.10, 1.5.13, 1.5.15,  

  

 

 

1.6.1, 1.6.5, 1.7.2, 1.7.4.1 

 
Die Inbetriebnahme der unvollständigen Maschine ist solange untersagt, bis die Konformität der Maschine, in 
welche die unvollständige Maschine eingebaut wurde, mit der Maschinenrichtlinie 2006/42/EG festgestellt 
ist. 
The partly completed machinery must not be put into service until the final machinery into which they have 
been incorporated has been declared in conformity with the provisions of Machinery Directive 2006/42/EC. 
 
Wir erklären, dass die speziellen technischen Unterlagen nach Anhang VII Teil B erstellt wurden und ver-
pflichten uns, diese auf Verlangen den Aufsichtsbehörden in digitaler Form zu übermitteln.  
We declare that the relevant technical documentation acc. to Annex VII Part B has been prepared and agree 
to submit it to the national authorities in digital form on request. 
 
Bevollmächtigter für die Zusammenstellung der speziellen technischen Unterlagen: 
Authorised person to compile the relevant technical documentation: 

 

 

 
Frank Steuer 

VEM motors GmbH 

  

 

Carl-Friedrich-Gauß-Strasse 1 
38855 Wernigerode 
Germany 

 

 
Wernigerode, <

Datum>

 

Wernigerode, <

date>

 

 

…………………………………………… 
Wolfgang Wiedemann 
Leiter Qualitätssicherung 
Head of Qualit

y Dept

 

Содержание W52R 355 Series

Страница 1: ...g and maintenance instructions Explosion proof three phase asynchronous motors with squirrel cage rotor for high voltage Ignition protection types Increased safety eb and ec Protection by enclosure t...

Страница 2: ...ge First edition 09 2015 11 2015 Annex 2 Update of EU Declaration of Conformity 01 2016 Change of section 5 7 to 5 8 Section 5 7 entry parts new Annex 4 new Change in the wording for the heating ca bl...

Страница 3: ...3 Risk assessment with regard to possible sparking in Ex eb IIC 3 Information about ignition protection type increased safety ec 3 1 Protective principle labelling 3 2 Risk assessment with regard to...

Страница 4: ...make changes to the product the technical data or the assembly operating and maintenance instructions without prior notice Designs technical data and illustra tions are only ever binding with written...

Страница 5: ...ng to IEC EN 60034 5 for motors used in zones 1 2 and 22 is a minimum of IP 55 For use in zone 21 the motors are designed to meet IP 65 as a minimum Only electrical machines with the approved type of...

Страница 6: ...erved 1 6 Transport and storage Any damage detected on delivery must be reported to the transport company immediately if necessary commissioning must be prevented Transport eyes attachment points are...

Страница 7: ...ain the temperature class and the permissible operating temperature The motor must not be enclosed Compare current type mains voltage and frequency Pay attention to the circuitry Observe rated current...

Страница 8: ...ions When inserting the supply cables into the terminal box make sure that the cables have strain relief The in side of the terminal boxes must be kept clean The seals must be undamaged and correctly...

Страница 9: ...eration If there are changes compared to normal operation e g increased tempera tures noises and vibrations the machine must be switched off in case of doubt The cause must be determined and the manuf...

Страница 10: ...ating manual must be observed Operation from the frequency inverter for use in zone 2 22 Ex II 3G Ex II 3D Operation with the frequency inverter is only permitted within the operating points specified...

Страница 11: ...ts are stated on the rating plate or on the EC Type Examination Certificate If the certificate number ends in an X special conditions on the EC Type Examination Certificate must be observed Electrical...

Страница 12: ...gap with squirrel cage rotors A risk assessment has been carried out by the manufacturer regarding possible sparking in the air gap of squirrel cage rotors If the sum of the factors is greater than 6...

Страница 13: ...tures of surfaces on which dust may be deposited or which may come into contact with a cloud of dust are kept below the temperatures specified in this standard All parts with electrical sparks or temp...

Страница 14: ...ox optional star point box The stator housing with feet is made of grey cast iron the bearing plates and terminal box are made of grey cast iron For high voltage motors a welded steel construction is...

Страница 15: ...connections must then be assembled with locking nuts taking into account the thickness of the plate The diameter of these through holes must be selected in accordance with DIN EN 50262 5 8 Standstill...

Страница 16: ...layers of dust lead to a temperature increase on the surface of the motor Dust deposits on motors and even their complete filling with dust must there fore be avoided as far as possible by appropriate...

Страница 17: ...t therefore be strictly observed by taking the following steps among others Limiting the total paint or resin layer thickness according to the explosion group to IIA IIB Total coating thickness 2 mm I...

Страница 18: ...ts list may be used this applies in particular to seals and connecting parts The following information is required when ordering spare parts Spare part designation Motor type Motor number 12 Disposal...

Страница 19: ...allation operating and maintenance instructions English Explosion proof three phase asynchronous motors with squirrel cage rotor for high voltage 815001 Edition 09 2020 19 13 Terminal box construction...

Страница 20: ...5 4 1 5 5 1 5 6 1 5 7 1 5 8 1 5 9 1 5 10 1 5 13 1 5 15 1 6 1 1 6 5 1 7 2 1 7 4 1 Die Inbetriebnahme der unvollst ndigen Maschine ist solange untersagt bis die Konformit t der Maschine in welche die un...

Страница 21: ...Supplementary installation operating and maintenance instructions English Explosion proof three phase asynchronous motors with squirrel cage rotor for high voltage 815001 Edition 09 2020 21 Annex 2...

Страница 22: ...Supplementary installation operating and maintenance instructions English Explosion proof three phase asynchronous motors with squirrel cage rotor for high voltage 815001 Edition 09 2020 22...

Страница 23: ...tion of the flange is determined by the motor manufacturer Before putting the motor into operation the free volume of the motor enclosure must be purged with inert gas if necessary after ignition risk...

Страница 24: ...d on the equipment rating plate or terminal box Alternatively the number and position of the entry threads are indicated on the dimension drawing of the mo tor Unless otherwise ordered cable glands fr...

Страница 25: ...instead be approved according to IECEx or if selected by the plant operator they must be approved according to IECEx The motors are labelled as IECEx compliant For IECEx approved motors references to...

Отзывы: