SD710 Series Servo Drive User Manual Appendix
9
Setting value: 0x05
Symbol
Torque limiting in
Trigger
method
Control
mode
TLT
This signal output is ON when the output torque of the motor is
within the setting range.
This signal output is OFF when the output torque of the motor is
beyond the setting range.
high and low
levels
□
P
□
S
□
T
Setting value: 0x06
Symbol
Speed limit in progress
Trigger
method
Control
mode
VLT
In torque mode:
This signal output is ON when the speed of the motor is beyond the
set speed limit range.
This signal output is OFF when the speed of the motor is within the
set speed limit.
high and low
levels
□
T
Setting value: 0x07
Symbol
Brake switch signal
Trigger
method
Control
mode
BK
Brake output signal. When this signal is invalid, the brake power is
off. The brake acts, and the motor is in position lock state.
When valid, the holding brake power is on, the holding brake is
released, and the motor can rotate.
high and low
levels
□
P
□
S
□
T
Setting value: 0x08
Symbol
Warning signal
Trigger
method
Control
mode
WARN
This signal output is ON when the current drive is in the warning
signal state.
This signal output is OFF when there is no warning signal status for
the current drive.
high and low
levels
□
P
□
S
□
T
Setting value: 0x09
Symbol
Positioning near signals
Trigger
method
Control
mode
NEAR
This signal output is ON when the current position deviation is
within the position near signal threshold (Pn260).
This signal output is OFF when the current position deviation is
beyond the position near signal threshold (Pn260).
high and low
levels
□
P
□
S
□
T