SD710 Series Servo User Manual Chapter 9 Parameter description
59
Note
:
①
Function code Pn301 and external terminal speed direction (SPD-D) are valid for both the analog speed
command and the internal register speed command.
②
The logic for combining function code Pn301 with the external terminal speed direction (SPD-D) is as follows (using
the CCW direction as a forward reference).
Setting
value
Instructions
Note
0
Same direction as current speed
command
-
1
Reverse with current speed
command
-
Pn302
Speed command low-pass filtering
О
Communication
address: 0x0302
Factory value: 0.40
Setting range: 0.00 ~ 655.35
Unit: ms
Control mode.
□
S
Parameter
Description
Applying 1 low-pass filter to the speed command input makes the speed command smooth.
Note:
Valid for both internal digital analog and external analog.
Pn303
Speed control switch 1
■
Communication
address: 0x0303
Factory value:
0x0000
Setting range: 0x0000~0x2222
Unit: N/A
Control mode.
□
S
63
.
2
%
Speed
Time
ms
Pn302
100
%
Speed after filter
Speed before filter