SD710 Series Servo User Manual Chapter 9 Parameter description
76
Pn608
Input terminal X8 configuration [CN1-30]
О
Communication
address: 0x0608
Factory value: 0x0000
Setting range: 0x0000~0x112F
Unit: N/A
Control mode.
□
P
□
S
□
T
Function assignment value
00
Invalid
01
See "Schedule 1 Input Terminal Function Definitions".
...
2F
Input terminal contact properties
0
Normally open
1
Normally closed
Input terminal signal source
0
External hardware terminal X8
1
Internal software status bits given by Pn630.Bit7
Pn611
Output terminal Y1 configuration [CN1-6/7]
О
Communication
address: 0x0611
Factory value: 0x0001
Setting range: 0x0000~0x110F
Unit: N/A
Control mode.
□
P
□
S
□
T
Function assignment value
00
See "Schedule 2 Output Terminal Function Definitions".
...
0F
Output terminal contact properties
0
Normally open
1
Normally closed
Output terminal signal source
0
Function Code Pn610 Distribution Signal Control
1
Function code Pn631.Bit0 bit control
3rd 2nd 1st 0th
3rd 2nd 1st 0th
X
Y
Z
W
X
Y
Z
W