SD710 Series Servo Drive User's Manual Chapter 7 Auxiliary Functions
32
assist
meri
torious
d
eed
or
service
capab
le
8
Press the "MODE/SET" button to enter the damping gain
setting interface, as shown in the figure on the left.
9
Press the "UP", "DOWN" and "DATA/SHIFT" keys to adjust the
current vibration suppression damping value.
While checking the damping effect, gradually increase the
damping gain setting in 10% steps from 0% to 200%. If the
damping gain reaches 200% and the damping effect is not
obtained, terminate the setting and reduce the control gain by
single parameter adjustment.
10
Press the "DATA/SHIFT" key for about 1 second to exit.
7.20 Forced output terminal signal (Fn300)
In the process of commissioning the drive and the upper computer, the output terminal (Y) of the servo drive is required
to force the output signal for the upper computer to debug, which can be achieved by this auxiliary function
(1) Pre-implementation recognition matters
The following confirmations shall be achieved when enforcing the output.
●
The parameter prohibition function (Fn010) is not set to " Prohibit writing ".
● Servo is OFF
(2) Operation steps
The procedure is shown below.
Steps
Panel display
Keys used
Operations
1
Press the "MODE/SET" key to select the auxiliary
function. Adjust by pressing the "UP" and "DOWN" keys
until Fn000 is displayed.
2
Adjust by pressing the "UP" or "DOWN" key until Fn300
is displayed.
3
Press the "DATA/SHIFT" key for about 1 second to
display the forced output symbol "doFor".
4
Press the "Mode" key to enter the forced output state. By
default, all output terminals are in "oFF" state. The
display symbol is shown on the left picture.
5
Press the "Up" key, the corresponding output terminal is
"on".
Press the "Down" button, the corresponding output
terminal will be "oFF".
6
Press the "DATA/SHIFT" key for about 1 second to
return to the "Fn300" display.
Note: The status of the digital tube corresponding to the output signal is shown below.
Display LED
number
CN1 input pin
number
Signal
Name
1
CN1-6/7
Y 1
MODE/SET
Data/
MODE/SET
Data/
MODE/SET
Data/
MODE/SET
Data/
MODE/SET
Data/
MODE/SET
Data/
MODE/SET
Data/
MODE/SET
Data/
MODE/SET
Data/
1
2
3
4
5
6
No.
Up: ON
Down: OFF