SD710 Series Servo Drive User's Manual Chapter 7 Auxiliary Functions
17
assist
meri
torious
d
eed
or
service
capab
le
7.11 Display of motor model information (Fn011)
This auxiliary function is used to display the motor model information, which includes the motor code, power rating, current
rating (peak), and maximum current (peak).
The procedure is shown below.
Steps
Panel display
Keys used
Operations
1
Press MODE/SET to select the auxiliary function. Adjust
by pressing UP or DOWN until Fn000 is displayed.
2
Adjust by pressing UP or DOWN until Fn011 is
displayed.
3
Pressing the DATA/SHIFT key for about 1 second
displays the servo motor voltage code.
No.
Type
V.0220
AC220V
V.0380
AC 380V
4
Pressing the MODE/SET key displays the servo motor
capacity.
The example indicates 200W.
5
Pressing the MODE/SET key displays the rated current
(peak) of the servo motor.
The example indicates 3.1A.
6
Pressing MODE/SET displays the servo motor's encoder
type and resolution.
Encoder type
Encoder resolution
No.
Types
No.
Resolution
0
Incremental
0
Line 2500
1
Multi-turn
absolute
17
17 bits
2
Single-turn
absolute
20
20 bits
-
-
23
23 bits
-
-
24
24 bits
7
Press the "DATA/SHIFT" key to return to the "Fn011"
display.
MODE/SET
Data/
MODE/SET
Data/
MODE/SET
Data/
MODE/SET
Data/
MODE/SET
Data/
MODE/SET
Data/
MODE/SET
Data/
Servo motor capacity
(
Value
×
10
W
)
Servo motor rated current
(
Value
×
0
.
1
A
)