SD710 Series Servo Drive User Manal Chapter 11 Communication
71
Description
Same value as 1C32-0Ah
Sub-index
0B
h
Name
Number of lost sync events
Structure
-
Data Type
Uint16
Range
-
Mapping Option
NO
Accessibility
RO
Default
-
Sub-index
0C
h
Name
Cycle over count
Structure
-
Data Type
Uint16
Range
-
Mapping Option
NO
Accessibility
RO
Default
-
Sub-index
20
h
Name
Synchronization error
Structure
-
Data Type
BOOL
Range
-
Mapping Option
NO
Accessibility
RO
Default
-
Description
TURE: Sync is active and no error occurred. False: Sync is not active or no sync error
occurred.
11.3.6.4 6000h Parameter Group Object Details
Character Descriptions
Character
Description
HM
Home position return mode
CSP
Periodic synchronous position mode
PP
Profile position mode
CSV
Periodic synchronous velocity mode
PV
Profile velocity mode
CST
Periodic ProfileTorque Mode
PT
Profile torque mode
Object 603Fh
HM
CSP
PP
CSV
PV
CST
PT
Index
603F
h
Name
Error Code
Structure
VAR
Data Type
Uint16
Range
Uint16
Mapping Option
Y
Accessibility
RO
Default
-
Description
The fault code is the error that occurred on the last operation. Check the fault list for details.
Object 6040h
HM
CSP
PP
CSV
PV
CST
PT
Index
6040
h
Name
Control Word
Structure
VAR
Data Type
Uint16
Range
Uint16