Chapter 8 Functional Parameter Table
ACH200 Series High Voltage Variable Frequency Speed Control System Operating Manual
95
F7.03
Torque
input
lower limit value
0.00%~100.00%
0.00%
●
△
0x703
F7.04
The lower limit
corresponds
to
the setting
-200.00%~200.00%
0.00%
●
△
0x704
F7.05
Torque
input
upper limit value
0.00%~100.00%
100.00%
●
△
0x705
F7.06
The upper limit
corresponds
to
the setting
-200.00%~200.00%
100.00%
●
△
0x706
F7.07
Given a first-
order
filtering
time
0.000s~6.000s
0.100s
●
△
0x707
F7.08
Upper limit of
output torque
0.0%~250.0%
150.0%
●
△
0x708
F7.09
Lower limit of
output torque
0.0%~250.0%
0.0%
●
△
0x709
F7.10
Torque control
positive
speed
limit selection
0: Function code F7.12
setting
1: Reserve
2: VS
╳
F7.12
3: Reserve
4: AS
╳
F7.12
5: Reserve
6: RS485 Communication
╳
F7.12
7: CAN Card
╳
F7.12
8: Extension Card
╳
F7.12
0
●
△
0x70A
F7.11
Torque control
reversing speed
limit selection
0: Function code F7.13
setting
1: Reserved
2: VS
╳
F7.13
3: Reserve
4: AS
╳
F7.13
5: Reserve
6: RS485 Communication
╳
F7.13
7: CAN Card
╳
F7.13
8: Extension Card
╳
F7.13
0
●
△
0x70B
F7.12
Torque control
maximum speed
limit for forward
rotation
0.0%~100.0%
100.0%
●
△
0x70C
F7.13
Torque control
reversal
maximum speed
limit
0.0%~100.0%
100.0%
●
△
0x70D
8.1.9 F8 V/F Control Parameters
Functio
n Code
Function code
name
Setting value range and
definition
Factory
settings
Prop
erties
Address
F8.00
Linear V/F curve 0: linear V/F curve;
0