Chapter 7 Modbus Communication Protocol
ACH200 Series High Voltage Variable Frequency Speed Control System Operating Manual
70
Command code
08H
Detection code high bit
00H
Detection code low bit
00H
Data high bit
13H
Data low bit
88H
CRC CHK low bit
EDH
CRC CHK high bit
5DH
END
3.5 bytes transmission time
RTU slave response information (in case of exception):
START
3.5 bytes transmission time
Slave address
01H
Command code
88H
Error code
03H
CRC CHK low bit
06H
CRC CHK high bit
01H
END
3.5 bytes transmission time
7.5 Communication Control Parameter Group Address Description
ACH200 series function parameter address representation rules.
The address of the register is the function parameter serial number of the AC drive, which is
divided into two parts: high byte and low byte. The high byte indicates the group serial number
where the functional parameter is located, and the low byte indicates the group serial number of the
functional parameter, which needs to be converted to hexadecimal.
The high byte of the address field is defined as follows:
Parameter group code number
Parameter address of this group
F0 Basic parameter group
0x00xx
(
No deposit EEPROM
)
0x10xx
(
Deposit EEPROM
)
F1 Operation control parameter
group
0x01xx
(
No deposit EEPROM
)
0x11xx
(
Deposit EEPROM
)
F2 Switching terminal parameter
group
0x02xx
(
No deposit EEPROM
)
0x12xx
(
Deposit EEPROM
)
F3 Analog terminal parameter
group
0x03xx
(
No deposit EEPROM
)
0x13xx
(
Deposit EEPROM
)
F4 Keyboard parameter group
0x04xx
(
No deposit EEPROM
)
0x14xx
(
Deposit EEPROM
)
F5 Motor parameter group
0x05xx
(
No deposit EEPROM
)
0x15xx
(
Deposit EEPROM
)
F6 Vector control parameter set
0x06xx
(
No deposit EEPROM
)
0x16xx
(