Chapter 8 Functional Parameter Table
ACH200 Series High Voltage Variable Frequency Speed Control System Operating Manual
106
FC.13
PLC
multi-
segment speed14
0.00Hz~maximum
frequency
40.00Hz
●
△
0xC0D
FC.14
PLC
multi-
segment speed15
0.00Hz~maximum
frequency
30.00Hz
●
△
0xC0E
FC.15
PLC operation
mode selection
LED one digit: cyclic mode
0: Stop after single cycle
1: Continuous cycle
2: Hold final value after
single cycle
LED ten digits: timing unit
0: Second
1: minute
2: Hour
LED
hundred
digits:
reserved
LED thousand digits: start
mode
0: Rerun from the first stage
1: Rerun from the stage of
the stop moment
2: Continue running with the
remaining time of the phase
of the stop moment
0000
●
△
0xC0F
FC.16
PLC section 1
running time
0.0s/m/h~6500.0s/m/h
10.0
(
s/m/h
)
●
△
0xC10
FC.17
PLC section 2
runtime
0.0s/m/h~6500.0s/m/h
10.0
(
s/m/h
)
●
△
0xC11
FC.18
PLC section 3
runtime
0.0s/m/h~6500.0s/m/h
10.0
(
s/m/h
)
●
△
0xC12
——
——
——
——
——
——
FC.19
PLC section 4
runtime
0.0s/m/h~6500.0s/m/h
10.0
(
s/m/h
)
●
△
0xC13
FC.20
PLC segment 5
runtime
0.0s/m/h~6500.0s/m/h
10.0
(
s/m/h
)
●
△
0xC14
FC.21
PLC segment 6
runtime
0.0s/m/h~6500.0s/m/h
10.0
(
s/m/h
)
●
△
0xC15
FC.22
PLC segment 7
operation time
0.0s/m/h~6500.0s/m/h
10.0
(
s/m/h
)
●
△
0xC16
FC.23
PLC section 8
runtime
0.0s/m/h~6500.0s/m/h
10.0
(
s/m/h
)
●
△
0xC17
FC.24
PLC section 9
runtime
0.0s/m/h~6500.0s/m/h
10.0
(
s/m/h
)
●
△
0xC18
FC.25
PLC section 10
runtime
0.0s/m/h~6500.0s/m/h
10.0
(
s/m/h
)
●
△
0xC19
FC.26
PLC section 11
runtime
0.0s/m/h~6500.0s/m/h
10.0
(
s/m/h
)
●
△
0xC1A
FC.27
PLC section 12
runtime
0.0s/m/h~6500.0s/m/h
10.0
(
s/m/h
)
●
△
0xC1B
FC.28
PLC section 13
operation time
0.0s/m/h~6500.0s/m/h
10.0
(
s/m/h
)
●
△
0xC1C
FC.29
PLC segment 14
runtime
0.0s/m/h~6500.0s/m/h
10.0
(
s/m/h
)
●
△
0xC1D
——
--
——
——
——
——
FC.30
PLC section 15 0.0s/m/h~6500.0s/m/h
10.0
●
△
0xC1E