AC70T Crane Purpose VFD Manual
51
F0.14
ACC time 1
0.01
~
650.00s
10.0s
F0.15
DEC time 1
0.01
~
650.00s
2.0s
F2.00
Multifunction input
terminal 1(X1)
FWD
1
F2.01
Multifunction input
terminal 2(X2)
REV
2
F2.02
Multifunction input
terminal 3(X3)
Multispeed terminal 1
8
F2.03
Multifunction input
terminal 4(X4)
Multispeed terminal 2
16
F2.04
Multifunction input
terminal 5(X5)
Multispeed terminal 3
17
F2.05
Multifunction input
terminal 6(X6)
Multispeed terminal 4
18
F2.06
Multifunction input
terminal 7(X7/PUL)
Malfunction reset
19
F2.45
Output terminal 1
Brake control function
1
F2.46
Relay output 1
Fault trip alarm1
4
F2.47
Relay output 2
Brake control function
1
F3.53
A0 output signal selection
Frequency output
LED “00” digit
: Reserved
LED “000” digit
: Reserved
0040
FC.00
PLC Speed 1
0.00
~
Max frequency
20.00Hz
FC.02
PLC Speed 3
0.00
~
Max frequency
35.00Hz
FC.06
PLC Speed 7
0.00
~
Max frequency
45.00Hz
FC.14
PLC Speed 15
0.00
~
Max frequency
50.00Hz
Fd.07
Modbus communication
fault action mode
selection
No checkout overtime fault
0
FF.00
Application type selection
Rotating mechanism
3
FF.36
Rotary flexible control
option
LED ‘0’ digit: rotary flexible control
0: off 1: open
LED ‘00’ digit: flexible control
acceleration and deceleration time
0: off 1: open
0011
FF.37
Flexible control starting
deviation frequency
0.00
~
20.00Hz
2.50Hz