AC70T Crane Purpose VFD Manual
34
F6.03
ASR switch frequency 1
0.00
~
Max frequency
0.00Hz
●
0x603
F6.04
ASR (speed loop)
proportional gain 2
0.01
~
100.00
10.00
●
0x604
F6.05
ASR (speed loop) integral
time 2
0.000
~
6.000s
0.500s
●
0x605
F6.06
ASR filter time 2
0.0
~
100.0ms
0.0ms
●
0x606
F6.07
ASR switch frequency 2
0.00
~
Max frequency
5.00Hz
●
0x607
F6.08
Electric motor torque limit
0.0
~
250.0%
180.0%
●
0x608
F6.09
Power generation torque
limit
0.0
~
250.0%
180.0%
●
0x609
F6.10
Current loop D-axis
proportional gain
0.001
~
4.000
1.000
●
0x60A
F6.11
Current loop D-axis
integral gain
0.001
~
4.000
1.000
●
0x60B
F6.12
Current loop Q-axis
proportional gain
0.001
~
4.000
1.000
●
0x60C
F6.13
Current loop Q-axis
integral gain
0.001
~
4.000
1.000
●
0x60D
F6.14
Reserved
0x60E
F6.15
Vector control motor slip
compensation
0.0
~
250.0%
100.0%
●
0x60F
F6.16
Vector control generator
slip compensation
0.0
~
250.0%
100.0%
●
0x610
F6.17
Reserved
0x611
F6.18
Position compensation
control
0:OFF 1:ON
0
●
0x612
F6.19
compensation gain
0.0
~
250.0%
10.0%
●
0x613
F6.20
compensation limit
0.0
~
100.0%
0.1%
●
0x614
F6.21
compensation effective
range
0.0
~
100.0%
10.0%
●
0x615
F6.22
Over excitation braking
gain
0.0
~
500.0%
100.0%
●
0x616
F6.23
Over excitation braking
amplitude limit
0.0
~
250.0%
100.0%
●
0x617
F6.24
Vector control energy
saving function
0:OFF 1:ON
0
●
0x618
F6.25
Energy saving control
0.0
~
80.0%
50.0%
●
0x619
F6.26
Energy saving control
low-pass filter
0.000
~
6.000s
0.010s
●
0x61A
F6.27
Motor constant power
area power limit
0.0
~
250.0%
150.0%
●
0x61B
F6.28
Motor weak magnetic
current upper limit
0.0
~
250.0%
60.0%
●
0x61C
F6.29
Motor weak magnetic
0.0
~
200.0%
0.0%
●
0x61D