AC70T Crane Purpose VFD Manual
58
4.18 Monitor Code
Access ‘C’ parameter group by pressing ‘PRG’ for more than 2s; check the current state of inverter.
Function
Code
Function name
Range of settings and
definition
Address
C-00
Given frequency
0.01Hz 2100H
C-01
Output frequency
0.01Hz 2101H
C-02
Output current
0.1A 2102H
C-03
Input voltage
0.1V 2103H
C-04
Output voltage
0.1V 2104H
C-05
Machine speed
1RPM 2105H
C-06 Given
torque
0.1%
2106H
C-07 Output
torque
0.1%
2107H
C-08
PID given value
0.1% 2108H
C-09
PID feedback value
0.1% 2109H
C-10 Output
power
0.1%
210AH
C-11
Bus voltage
0.1V
210BH
C-12
Module temperature 1
0.1
℃
210CH
C-13
Module temperature 2
0.1
℃
210DH
C-14
Input terminal X on state
See input terminal diagram
210EH
C-15
Output terminal Y on state
See output terminal diagram
210FH
C-16
Analog VS input value
0.001V 2110H
C-17
Analog AI input value
0.001V/0.001mA 2111H
C-18
Analog AS input value
0.001mA 2112H
C-19
Impulse signal PUL input
0.001kHz 2113H
C-20
Analog output AO1
0.01V 2114H
C-21
Analog output AO2
0.01V/0.01mA/0.01kHz 2115H
C-22
Counting value of counter
2116H
C-23
Running time after electrifying
0.1h
2117H
C-24
Local accumulative running time
Hour
2118H
C-25
Inverter power level
kW 2119H
C-26
Inverter rated voltage
V 211AH
C-27
Inverter rated current
A 211BH
C-28
Software version
211CH
C-29
PG feedback frequency
0.01Hz 211DH
C-30
Extended terminal input state
See input terminal diagram
211EH
C-31
Extended terminal output state
See output terminal diagram
211FH
C-32-C-34 Reserved
2120H
C-35
Counted time of timer
sec/min/h
2123H
C-36
Fault pre alarm code
2124H