AC70T Crane Purpose VFD Manual
16
FF.02 Run
command
control
LED ‘0’ digit
: reverse control during
operation
0: not allowed to run
1: Allow reverse operation
LED ‘00’ digit
: zero-crossing
frequency jump function
0: Invalid 1: Valid
LED ‘000’ digit
: Reserved
0010
〇
0xF02
FF.03
Restart waiting delay
during braking
0.00-10.00s
0.30s
〇
0xF03
FF.04
Brake release current
coefficient
10.0-100.0%
30.0%
〇
0xF04
FF.05
Zero crossing
frequency
0.00-10.00Hz
1.00Hz
〇
0xF05
FF.06
Up release frequency
0.00-10.00Hz
2.00Hz
〇
0xF06
FF.07
Up brake frequency
0.00-10.00Hz
2.00Hz
〇
0xF07
FF.08
Down release
frequency
0.00-10.00Hz
2.00Hz
〇
0xF08
FF.09
Down brake frequency
0.00-10.00Hz
2.00Hz
〇
0xF09
FF.10
Delay before the lift
0.00-10.00s
0.20s
〇
0xF0A
FF.11
Delay after the lift
0.00-10.00s
0.10s
〇
0xF0B
FF.12
Delay before the
upward brake
0.00-10.00s
0.00s
〇
0xF0C
FF.13
Delay after the up brake
0.00-10.00s
0.50s
〇
0xF0D
FF.14
Down delay before the
release
0.00-10.00s
0.30s
〇
0xF0E
FF.15
Delay after down
release
0.00-10.00s
0.10s
〇
0xF0F
FF.16
Delay before the brake
0.00-10.00s
0.00s
〇
0xF10
FF.17
Delay after down brake
0.00-10.00s
0.30s
〇
0xF1A
FF.18
-FF.24
Reserved
FF.25
Current judgment
enable during operation
0
~
1
1
〇
0xF19
FF.26
In-service current
detection
0%
~
50%
5%
〇
0xF1A