AC70T Crane Purpose VFD Manual
42
FC.15
PLC running Mode
selection
LED “0” digit: cycle mode
0: Stop after single cycle
1: Continuous cycles
2: Keep final value after single cycle
LED “00” digit: Time unit
0: second
1: minute
2: hour
LED “000” digit: Power down
memory mode
0: not save
1: save
LED “0000” digit:Start-up mode
0: Restart from the 1st stage
1: Restart from the stop stage
2: Continue from the time when stop
0000
●
0xC0F
FC.16
PLC 1st Step running
0.0
~
6500.0(s/m/h)
10.0
●
0xC10
FC.17
PLC 2nd Step running
time
0.0
~
6500.0(s/m/h)
10.0
●
0xC11
FC.18
PLC 3rd Step running
0.0
~
6500.0(s/m/h)
10.0
●
0xC12
FC.19
PLC 4th Step running
0.0
~
6500.0(s/m/h)
10.0
●
0xC13
FC.20
PLC 5th Step running
0.0
~
6500.0(s/m/h)
10.0
●
0xC14
FC.21
PLC 6th Step running
0.0
~
6500.0(s/m/h)
10.0
●
0xC15
FC.22
PLC 7th Step running
0.0
~
6500.0(s/m/h)
10.0
●
0xC16
FC.23
PLC 8th Step running
0.0
~
6500.0(s/m/h)
10.0
●
0xC17
FC.24
PLC 9th Step running
0.0
~
6500.0(s/m/h)
10.0
●
0xC18
FC.25
PLC 10th Step running
time
0.0
~
6500.0(s/m/h)
10.0
●
0xC19
FC.26
PLC 11th Step running
time
0.0
~
6500.0(s/m/h)
10.0
●
0xC1A
FC.27
PLC 12th Step running
time
0.0
~
6500.0(s/m/h)
10.0
●
0xC1B
FC.28
PLC 13th Step running
time
0.0
~
6500.0(s/m/h)
10.0
●
0xC1C
FC.29
PLC 14th Step running
time
0.0
~
6500.0(s/m/h)
10.0
●
0xC1D
FC.30
PLC 15th Step running
time
0.0
~
6500.0(s/m/h)
10.0
●
0xC1E
FC.31
PLC 1
st
-15th Step
direction and ADD/DEC
time
LED “0” digit: current step run
direction
0: FWD
1: REV
LED “00” digit: ACC/DEC time in
0000
●
0xC1F
FC.32
0000
●
0xC20
FC.33
0000
●
0xC21
FC.34
0000
●
0xC22
FC.35
0000
●
0xC23