AC70T Crane Purpose VFD Manual
23
F1.32-F1.34
Reserved
0x120
F1.35
Power off restart action
selection
0: Invalid
1: Valid
0
〇
0x123
F1.36
Power off restart waiting
time
0.00
~
60.00s
0.50s
〇
0x124
F1.37
Reserved
0x125
F1.38
JOG running frequency
0.00-Max frequency
5.00Hz
●
0x126
F1.39
JOG ACC time
0.01
~
650.00s
10.00s
●
0x127
F1.40
JOG DEC time
0.01
~
650.00s
10.00s
●
0x128
F1.41
Jump frequency 1
0.00-Max frequency
0.00Hz
●
0x129
F1.42
Jump frequency range 1
0.00-Max frequency
0.00Hz
●
0x12A
F1.43
Jump frequency 2
0.00-Max frequency
0.00Hz
●
0x12B
F1.44
Jump frequency range 2
0.00-Max frequency
0.00Hz
●
0x12C
4.4 Digital Terminal Parameter Group
NO.
Function description
Range of settings and definition
Factory
setting
Feature
Address
F2.00
Multifunction input
terminal 1(X1)
Refer to 4.2 Function Selection Table
1
〇
0x200
F2.01
Multifunction input
terminal 2(X2)
2
〇
0x201
F2.02
Multifunction input
terminal 3(X3)
4
〇
0x202
F2.03
Multifunction input
terminal 4(X4)
5
〇
0x203
F2.04
Multifunction input
terminal 5(X5)
6
〇
0x204
F2.05
Multifunction input
terminal 6(X6)
8
〇
0x205
F2.06
Multifunction input
terminal 7(X7/PUL)
0
〇
0x206
F2.07 Reserved
0
〇
0x207
F2.08
X1-X4 terminal trait
selection
0: On valid 1: Off valid
LED “0” digit: X1 terminal
LED “00” digit: X2 terminal
LED “000” digit: X3 terminal
LED “0000” digit: X4terminal
0000
●
0x208
F2.09
X5-X7 terminal trait
selection
0: On valid 1: Off valid
LED “0” digit: X5 terminal
LED “00” digit: X6 terminal
LED “000” digit: X7 terminal
LED “0000” digit::reserved
0000
●
0x209
F2.10
X1 valid detection delay
0.000-6.000S
0.010
●
0x20A