AC70T Crane Purpose VFD Manual
43
FC.36
this step
0: ACC/DEC time 1
1: ACC/DEC time 2
2: ACC/DEC time 3
4: ACC/DEC time 4
LED “000” digit: reserved
LED “0000” digit: reserved
0000
●
0xC24
FC.37
0000
●
0xC25
FC.38
0000
●
0xC26
FC.39
0000
●
0xC27
FC.40
0000
●
0xC28
FC.41
0000
●
0xC29
FC.42
0000
●
0xC2A
FC.43
0000
●
0xC2B
FC.44
0000
●
0xC2C
FC.45
0000
●
0xC2D
FC.46-FC.48
Reserved
0xC2E
FC.49
Swing frequency control
0: invalid 1:valid
0
●
0xC31
FC.50
Swing frequency
amplitude control
0:Relative to central frequency
1:Relative to max frequency
0
●
0xC32
FC.51
Reserved
0xC33
FC.52
Swing frequency
amplitude
0.0
~
100.0%
10.0%
●
0xC34
FC.53
Jump frequency
0.0
~
50.0%
10.0%
●
0xC35
FC.54
Swing frequency rising
time
0.00
~
650.00s
5.00s
●
0xC36
FC.55
Swing frequency falling
time
0.00
~
650.00s
5.00s
●
0xC37
FC.56
Reserved
0xC38
4.12 Communication Control Function Parameter Group
NO.
Function description
Range of settings and definition
Factory
default
Feature
Address
Fd.00
Main-slave machine
selection
LED “0” digit: Modbus main-slave
selection
0: Slave machine
1: Main machine
LED “00” digit: reserved
LED “000” digit: reserved
LED “0000” digit: reserved
0000
〇
0xD00
Fd.01
485 communication
address
1
~
247
1
〇
0xD01
Fd.02
Communication baud
rate selection
LED “0” digit: 485 communication
0: 1200 bps
1: 2400 bps
2: 4800 bps
3: 9600 bps
4: 19200 bps
0003
〇
0xD02