AC70T Crane Purpose VFD Manual
22
F1.07
Speed tracking stop
delay
0.00
~
60.00s
1.00s
〇
0x107
F1.08~F1.09
Reserved
0x108
F1.10
Stop mode
0: DEC stop
1: Free stop
0
●
0x10A
F1.11
DC braking initial
frequency when stop
0.00
~
50.00Hz
1.00Hz
〇
0x10B
F1.12
DC braking current
when stop
0.0
~
150.0%
60.0%
0x10C
F1.13
Reserved
0x10D
F1.14
DC braking holding time
when stop
0.0
~
60.0s
0.0s
〇
0x10E
F1.15
Detection frequency
when stop
0.00
~
50.00Hz
0.50Hz
●
0x10F
F1.16
ACC/DEC selection
LED “0” digit: time base selection
0: max frequency
1: fixed frequency 50Hz
2: set frequency
LED “00” digit: S ACC/DEC
selection
0: Beeline ACC/DEC
1: S Curve ACC/DEC
LED“000/0000”digit: reserved
LED “0000” digit: reserved
0010
〇
0x110
F1.17
ACC start S curve time
0.00
~
10.00
0.10s
〇
0x111
F1.18
ACC finish S curve time
0.00
~
10.00
0.10s
〇
0x112
F1.19
DEC start S curve time
0.00
~
10.00
0.10s
〇
0x113
F1.20
DEC finish S curve time
0.00
~
10.00
0.10s
〇
0x114
F1.21
ACC time 2
0.01
~
650.00s
10.00s
●
0x115
F1.22
DEC time 2
0.01
~
650.00s
10.00s
●
0x116
F1.23
ACC time 3
0.01
~
650.00s
10.00s
●
0x117
F1.24
DEC time 3
0.01
~
650.00s
10.00s
●
0x118
F1.25
ACC time 4
0.01
~
650.00s
10.00s
●
0x119
F1.26
DEC time 4
0.01
~
650.00s
10.00s
●
0x11A
F1.27
Emergency stop DEC
0.01
~
650.00s
1.00s
●
0x11B
F1.28
FWD&REV dead time
0.0
~
120.0s
0.0s
〇
0x11C
F1.29
Zero speed torque
frequency threshold
0.00
~
10.00Hz
0.50Hz
●
0x11D
F1.30
Zero speed torque
holding coefficient
0.0
~
150.0%
60.0%
●
0x11E
F1.31
Zero speed torque
holding time
0.0
~
6000.0s
If set 6000.0s, always hold
0
●
0x11F