AC70T Crane Purpose VFD Manual
2
1.2 Before Use
On receiving your order, please check the package and confirm intact before opening, and check if there’s any
damage, scratch or dirt (damages caused during transportation are not within the company's warranty). If there’s any
damage caused during transportation, please contact us or the transport company immediately. After confirming the
receipt of the goods intact, please re-confirm if the product and your order are consistent.
Model
Applicable
motor
Input
VOLT
Rated
Current
Model
Applicable
motor
Input
VOLT
Rated
Current
AC70T-T3-R75-B
0.75KW
3 Phase
380VAC
2.3A
AC70T-T3-037-B
37KW
3 Phase
380VAC
75A
AC70T-T3-1R5-B
1.5KW
3.7A
AC70T-T3-045-B
45KW
90A
AC70T-T3-2R2-B
2.2KW
5A
AC70T-T3-055-B
55KW
120A
AC70T-T3-004-B
4KW
10A
AC70T-T3-075-B
75KW
150A
AC70T-T3-5R5-B
5.5KW
13A
AC70T-T3-090-B
90KW
180A
AC70T-T3-7R5-B
7.5KW
17A
AC70T-T3-110
110KW
210A
AC70T-T3-011-B
11KW
25A
AC70T-T3-132
132KW
250A
AC70T-T3-015-B
15KW
32A
AC70T-T3-160
160KW
310A
AC70T-T3-018-B
18KW
38A
AC70T-T3-185
185KW
340A
AC70T-T3-022-B
22KW
45A
AC70T-T3-200
200KW
380A
AC70T-T3-030-B
30KW
60A
1.3 Technical criterion
Items
Criterion
Power
input
Voltage,frequency
Three phase 380V 50/60Hz ;
Allowable fluctuations
voltage unbalance rate:<3%; Frequency:±5%; aberration rate: as IEC61800-2
Input
Inverter Model
Output
Power Level
Series No.