AC70T Crane Purpose VFD Manual
45
Same as above
Fd.10
RS485 communication
t
fi
ti
0: Modbus communication
1
i l
t
i ti
0
●
0xD0A
4.13 Factory parameters corresponding to industry application macros
4.14 Lifting mechanism dedicated macro
NO.
Function description
Range of settings and definition
Factory
set (open
loop)
Factory set
(closed
loop)
F0.00
Motor control mode
0: Open loop vector control mode 1
4: PG high performance vector
control
0 4
F0.02
Run command channel
Controlled by terminals
1 1
F0.03
Frequency given source
channel A
Keyboard given frequency
0 0
F0.08
Keyboard number setting
frequency
0.00
~
max frequency
10.00Hz 10.00Hz
F0.14
ACC time 1
0.01
~
650.00s
6.0s
6.0s
F0.15
DEC time 1
0.01
~
650.00s
2.0s
3.0s
F2.00
Multifunction input terminal
1(X1)
FWD
1
1
F2.01
Multifunction input terminal
2(X2)
REV
2
2
F2.02
Multifunction input terminal
3(X3)
Malfunction reset
8
8
F2.03
Multifunction input terminal
4(X4)
Multispeed terminal 1
16
16
F2.04
Multifunction input terminal
5(X5)
Multispeed terminal 2
17
17
F2.05
Multifunction input terminal
6(X6)
Multispeed terminal 3
18
18
F2.06
Multifunction input terminal
7(X7/PUL)
Multispeed terminal 4
19
19
F2.45
Output terminal 1
Brake control function
33
33
F2.46
Relay output 1
Fault trip alarm1
4
4