AC70T Crane Purpose VFD Manual
10
A0
Analog monitor output, constitutes loop with GND.
Max output 2mA as frequency, voltage
+24V
24V auxiliary power supply output, constitutes loop 100mA
Y
Collector open circuit output; can set the
action-object by program.
DC24V/50mA
TA/TB/TC
Passive connector output; can set the action-object
by program.
3A/240VAC
●
Connection Function Specification of Switch Terminals
Switch Terminal
Selecting Position
Function Specification
S1
K1 AO1:0
~
20mA or 4
~
20mA current output
K2 AO1:0
~
10V voltage output
S2
K3 AI:0
~
20mA or 4
~
20mA input current
K4 AI:
0
~
10V input voltage
S3
K5 AO2:
0.0
~
100kHz (J1 on), open collector circuit output
K6 AO2:0.0
~
100kHz (J1 on), active source output
S4
K7
RS485: connect with 120
Ω
terminal resistor
K8 RS485:connect
without
120
Ω
terminal resistor
S5
J1
AO2:0.0
~
100kHz frequency output(PWM eddy current pulse wave
output)
J2 AO2:0
~
20mA or 4
~
20mA current output
J3 0
~
10V voltage output
S6
+24V
Short +24V terminal and PLC terminal
PLC
PLC terminal receiving external power input
COM
Short PLC terminal and COM terminal
S7
K9
Disconnect GND terminal and PE discharge loop
K10
Connect GND terminal and PE discharge loop
AS
VS
GND
GND
AO2
AO1
X1
X2
AI
+10V
COM
TC1
PLC
TA1
A+
+24V
X7/PUL
X4
X3
X5
TB2
X6
TA2
B-
Y
TB1
COM
TC2