13
Revision D November 2022
The QuadGuard
®
HS system may be installed on any of the following foundations using the
specified anchorage:
Foundation D: Asphalt Only
Foundation: 8” [200 mm] minimum A.C.
Anchorage:
Approved adhesive with
18” [460 mm] studs - 16 1/2” [420 mm] embedment
Important:
Systems mounted on asphalt must be replaced and mounted on
fresh, undisturbed asphalt if more than 10% of anchors are found to be loose,
broken, or show signs of pull out. If 10% or fewer anchors are damaged, replace
the damaged anchors in the existing asphalt. Anchor bolts used on systems
mounted on asphalt must be inspected every 6 months.
See Post Impact
Instructions and Maintenance and Repair instructions on page 54.
Foundation A: Concrete Pad or Roadway
Foundation: 150 mm [6”] minimum depth Portland Cement Concrete (P.C.C.)
Anchorage:
Approved adhesive
with 180
mm [7”] studs 140 mm [5 1/2”] embedment
Foundation B: Asphalt over P.C.C.
Foundation: 76 mm [3”] minimum asphalt concrete (A.C.) over 76 mm [3”] minimum P.C.C.
Anchorage: Length of anchor required is 460 mm [18”] 420 mm [16 1/2”] embedment
Foundation C: Asphalt over Compacted Subbase (C.S.)
Foundation: 150 mm [6"] minimum A.C. over 150 mm [6”] minimum C.S.
Anchorage:
Approved adhesive with 460
mm [18"] studs 420 mm [16 1/2”] embedment
Foundation Specifications
For Foundations A, B, C and D mentioned above:
A. C. (Asphalt Concrete)
AR-4000 A. C. (per ASTM D3381 '83) 3/4” Maximum, Medium (Type A or B) aggregate
Caution:
Walk-up inspections are recommended at least once every six
months for installations on asphalt.