COMMISSIONING
62
Installing current collector - PASK
Assembly instructions
Prerequisites:
Clean and tidy workplace.
Assembly steps:
1. Align the current collector with the conductor sys-
tem (phase center off).
NOTICE!
►
Installation dimension: 80 mm
►
Number of poles: 3-6
►
Phase spacing 15 mm
►
Max. current: 50 A
►
Tolerance X-direction: ± 15 mm
►
Tolerance Y-direction: ± 20 mm
►
Contact pressure: approx. 4 N per carbon brush
►
The current collector must be able to move freely.
Connecting cables may not restrict or impede
movement.
Installation dimension = 80
Installation dimension = 80