![Vahle VCL Series Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/vahle/vcl-series/vcl-series_translation-of-the-original-operating-instructions_3164861019.webp)
TECHNICAL DATA
17
*
When using an expansion section (max. 50A) - with a load of 100 A, place feed terminals (100 A) on the right
and left of the next rail section, and connect with a cable (bridging).
3.3
VMT
Tolerances
Conductor system X-axis:
[mm] ± 3
Conductor system Y-axis:
[mm] ± 3
Conductor rail connectors Z-axis:
[mm] 0.7 + 1 per side
Current collectors X-axis:
[mm] ± 15 (DEAS ± 12)
Current collectors Y-axis:
[mm] ± 20
Contact pressure current collector
[N] approx. 8
Operating conditions
Operating temperature
[°C] - 30 to + 55
Max. humidity at
[%]
ambient temperature 10°C to 40°C
98, non-condensing
Max. deviation of operating temperature
[K] 50
Flammability (insulator profile)
flame-retardant, self-extinguishing,
UL 94 V0
Application
Indoor installations
Technical specifications
Support profile version
Steel
Grid dimension of compact holder
[mm] 100
Bearer length
[mm] 6000
Max. hanger spacing (lateral/suspended)
[mm] 3500/3000
Technical specifications - system dependent
Number of poles
4-6
Temperature range
[°C] -30 to +55
Application area
Indoor installations
NOTICE!
UL certification
►
For design with UL certification, please consult the manufacturer.
Содержание VCL Series
Страница 95: ...INDEX 93 U Unloading 88...
Страница 96: ...CE Technical Documentation...