COMMISSIONING
47
CAUTION!
Danger of crushing between the individual components!
During assembly there is a risk of crushing of the extremities between the individual
components.
►
Take care of your extremities.
►
Wear personal protective equipment. (see Chapter: 2 )
NOTICE!
The conductor rail material is susceptible to corrosion.
Corrosion can occur when working on the conductor rail with tools.
►
Only tools that have not previously been used for ferritic materials may be used.
►
Own tools should be used for the different materials (aluminum, copper, stainless
steel).
►
Chip-forming work (grinding etc.) must not be performed in the vicinity of the con-
ductor rail system.
NOTICE!
The following points have to be strictly observed during assembly!
►
Appropriate handling of materials.
►
Clean and metallic bright surfaces on all contact points.
►
Smooth crossovers, free of burrs, of the conductor rail profiles at the ends in order
to avoid breakdowns and a high carbon brush wear.
►
Firm tightening of all screws using the screw lock provided and observing the stat-
ed tightening torques.
►
Exact alignment of the conductor rail to the guide system.
►
Damaged materials must not be installed.
►
Observe all applicable regulations governing installation of the plant.
5.2
Operation/decommissioning
5.2.1
Operation
Operation is understood to be trouble-free, normal operation. Check intervals as per the maintenance sched-
ule in Chapter: „7 “. If defects occur, stop using the system to prevent damage.
5.2.2
Decommissioning
Switch off the system and secure it against restarting. Disconnect the entire power supply from the system
physically.