COMMISSIONING
61
5.3.9
Collector
Single current collector assembly - EASL
Assembly instructions
Prerequisites:
Clean and tidy workplace.
Assembly steps:
1. Align the current collector with the conductor sys-
tem (phase center off).
NOTICE!
►
Installation dimensions: 55 mm
►
Suitable for funnel
►
Phase spacing 15 mm
►
Max. current: 20 A
►
Tolerance X-direction: ± 15 mm
►
Tolerance Y-direction: ± 20 mm
►
Contact pressure: approx. 4 N per carbon brush
►
The current collector must be able to move freely.
Connecting cables may not restrict or impede
movement.
Double current collector assembly - DEAS
Assembly instructions
Prerequisites:
Clean and tidy workplace.
Assembly steps:
1. Align the current collector with the conductor sys-
tem (phase center off).
NOTICE!
►
Installation dimensions: 80 mm
►
Phase spacing 15 mm
►
Max. current: 30 A
►
Tolerance X-direction: ± 12 mm
►
Tolerance Y-direction: ± 20 mm
►
Contact pressure: approx. 4 N per carbon brush
►
The current collector must be able to move freely.
Connecting cables may not restrict or impede
movement.