COMMISSIONING
60
5.3.8
Straight sections
NOTICE!
►
To reach the desired system length, normally only the last 1-2 profiles are adapted!
It is not recommended to shorten profiles within the system!
CAUTION!
►
To ensure smooth and impairment-free running of the current collectors/carbon
brushes, the cut surfaces must always be carefully deburred.
►
Shorter lengths may not be below 300 mm!
Assembly instructions
Requirements:
Clean and tidy workplace.
Required tools:
⚒
Tape measure
⚒
Handsaw, chop saw
⚒
File
Assembly steps:
1. Pull the copper profile out of the insulating housing for exactly 15 mm and make
sure that the copper is flush with the insulating profile on the other side.
2. Hold the tape measure to the copper and mark the desired length.
3. Cut the insulating profile including copper to length. Push the copper back 7.5 mm
into the insulating profile so that you now have 7.5 mm of copper protruding from
each side of the insulating profile.
4. The cut surface must be cleanly deburred. Then mount the profile in the respective
position.