background image

 

LAYOUT AND FUNCTION

42

 

4.5

System description VMT

The modular ALL-IN-ONE solution for your warehouse technology - VCL & VMT

The VCL compact conductor system is generally available as a two- and three-pin variant. Combining these two
conductor rails allows up to 6-pin conductor systems to be realized. In addition to the power supply for the shut-
tle technology, the VCL is also suited for use in SPW and pallet SRM applications as well as other compact mov-
ing and transfer carriage applications in the small and medium power range up to 100 amperes. 

With the new VAHLE multi-bearer, VAHLE has developed a product that is specially tailored to the many require-
ments of floor-guided storage and conveyor systems, such as storage and retrieval systems and transfer car-
riages. Please contact us in the case of other applications, e.g. in crane technology. Displacement and
positioning systems can of course also be used in parallel. A further plus for the user are the large hanger dis-
tances, which enable quick and cost-effective installation.

The following illustrations show configuration examples. From left to right, a 4-pin, 5-pin, and a 6-pin variant
demonstrate the variability of the system.

System features

• Supports several standard conductor systems
• Hanger spacing up to 3.5 meters
• Quick and easy installation using plug and clamping systems
• Mechanical protection of the conductor rail system
• Temperature-independent system rigidity
• Trade-association compliant design of the support profile
• Integration of optical travel sensor and positioning systems
• Universal hangers for all common upright profiles
• 4- to 6-pin; 40–100 A with identical installation space
• 12 to 500V
• IP2X contact protection
• Electrical protection through equipotential bonding
• Easy replacement of partial sections or individual sections

Содержание VCL Series

Страница 1: ...TRANSLATION OF THE ORIGINAL GERMAN OPERATING INSTRUCTIONS VCL COMPACT CONDUCTOR SYSTEM INSTALLATION MANUAL SYSTEM MANUAL MAINTENANCE MANUAL EN V 1 01...

Страница 2: ...pment 11 2 7 Safety devices 12 2 8 Conduct in case of danger or accident 12 2 9 Signage 13 3 Technical data 14 3 1 VCL2 14 3 2 VCL3 16 3 3 VMT 17 4 Layout and function 18 4 1 System description VCL2 V...

Страница 3: ...ning 47 5 2 1 Operation 47 5 2 2 Decommissioning 47 5 3 Installation VCL2 VCL3 48 5 3 1 Assembly preparation 48 5 3 2 Determining the system lengths 52 5 3 3 End segment with feed terminal fixpoint 54...

Страница 4: ...7 2 Wear parts 84 7 3 Conductor system maintenance 85 7 4 Current collector maintenance 86 7 5 Cleaning 87 8 Transport and storage 88 8 1 Safety instructions for transport and storage 88 8 2 Transpor...

Страница 5: ...ersonnel in the immediate vicinity The basic requirement for safe working is compliance with all specified safety instructions and instructions This documentation does not give instructions for operat...

Страница 6: ...icity that will result in death or serious injury unless avoided The actions to prevent the hazard are identified here WARNING The source of the hazard is described here This combination of a symbol a...

Страница 7: ...n of the manufacturer except for internal purposes 1 4 Disclaimer The information in this document has been compiled in consideration of applicable standards and regulations accepted rules of engineer...

Страница 8: ...product require the permission of the man ufacturer Genuine spare parts and manufacturer approved accessories provide safe ty The use of non approved parts voids any liability of the manufacturer Alw...

Страница 9: ...ductor rail is only to be used for indoor installations It can be mounted hanging or laterally Appropriate use includes following all the information in these instructions Any use beyond or other than...

Страница 10: ...ches control units pressure and sensing devices safety parts circuity breakers that have been used to unlock a system part or that can be used to connect electricity If this is not possible then the c...

Страница 11: ...rds that may arise from the special operating conditions at the instal lation site These must be implemented as facility instructions for the operation of the system Over the entire time the owner has...

Страница 12: ...ask Electrically qualified person see VDE 0105 100 Due to their professional training knowledge experience and knowledge of the relevant standards and regu lations professional electricians are able t...

Страница 13: ...ainst flying particles and liquid sprays Helmet Helmets protect against falling or flying parts and materials Gloves Gloves protect hands against chafing and abrasion cuts and punctures as well as aga...

Страница 14: ...egulations the following safety instructions must be observed The following accident prevention regulations UVV Germany respectively the new Accident Prevention Reg ulations Principles of Prevention D...

Страница 15: ...that the components are not live or in tension unauthorized approxima tion WARNING Danger from illegible signs Over time labels and signs can get dirty or can become unreadable in other ways which me...

Страница 16: ...2 x phase 1 x phase PE Cross section connection cable mm 6 16 Conductor material Copper CU or steel F Protection class IP2X Dielectric strength according to DIN 53481 kV mm 22 4 Volume resistivity acc...

Страница 17: ...collectors Y axis mm 20 Operating conditions Operating temperature C 30 to 55 Max humidity at ambient temperature 10 C to 40 C 98 non condensing Max deviation of operating temperature K 50 Flammabilit...

Страница 18: ...e 2 x phase PE Cross section connection cable mm 16 Conductor material Copper CU or steel F Protection class IP2X Dielectric strength according to DIN 53481 kV mm 22 4 Volume resistivity according to...

Страница 19: ...nditions Operating temperature C 30 to 55 Max humidity at ambient temperature 10 C to 40 C 98 non condensing Max deviation of operating temperature K 50 Flammability insulator profile flame retardant...

Страница 20: ...C or 60 volts DC The VDE finger shows that it cannot touch live parts The insulation rail covering the conductor rail offers good insulation for maximum safety Several wiper lines can be combined with...

Страница 21: ...the stated nom inal currents The reduction factors according to DIN VDE 0298 4 must be observed for the various laying procedures According to DIN EN 60204 1 and DIN EN 60204 32 the continuity of the...

Страница 22: ...LAYOUT AND FUNCTION 20 4 2 System overview VCL2 VCL3 System overview VCL2 2 pin 1 End segment 2 Conductor system 3 Transfer guide with without fixpoint 4 Hanger 5 Connector material 1 2 3 4 5...

Страница 23: ...LAYOUT AND FUNCTION 21 System overview VCL3 3 pin 1 End segment 2 Conductor system 3 Transfer guide with without fixpoint 4 Hanger 5 Connector material 1 2 3 4 5...

Страница 24: ...rted For exposed connectors strictly adhere to the spacing of 150 mm Arrangement example 2 Fixed end segment sliding end segment 1 Fixed end segment 2 Conductor system 3 Conductor system 4 Sliding end...

Страница 25: ...2 40F 4000SSD 0281544 00 Weight 100C kg 2 406 Weight 40F kg 2 190 Delivery length mm 4000 Hanger spacing mm 800 Segment Section Phase PE VCL2 100C 1000HSC 0281531 00 VCL2 100C 2000HSC 0281532 00 VCL2...

Страница 26: ...gers on request EndsegmentPhase VCL2 100C SSD 0281510 00 VCL2 40F SSD 0281516 00 Weight kg 0 324 Delivery length mm 1000 Segment Section Phase PE VCL2 100C HSC R 0281515 00 VCL2 100C HSC L 0281518 00...

Страница 27: ...A 50 Expansion section Phase PE DT DVCL2 100C HSC 0281507 00 DT DVCL2 40F HSC 0281509 00 Weight kg 0 324 Delivery length mm 1000 Max current A 50 Line feed Phase ES VCL2 100C SSD 50A 0281502 00 ES VCL...

Страница 28: ...kg 0 020 Current collector DEAS SA DEAS 2 30 2 SS 2 5 0 2 2 PA for control current 2823983 00 0 SA_DEAS 2 30 2 HS 2 5 0 2 2 PA for main power with PE 2823998 00 0 Weight kg 0 4 Number of poles 2 Phase...

Страница 29: ...for main current with PE 2823997 00 0 Current collector EASL SA EASL 20 2 SS 0 2 PA V E for control current 2823982 00 0 SA EASL 20 2 HS 0 2 2 PA V E for main current with PE 2823997 00 0 Weight kg 0...

Страница 30: ...5PH 6 3 Phase Black 2 5 4 5 2809171 00 2809173 00 AL FLA2 5PE 6 3 PE Green yellow 2 5 3 9 2809175 00 2809177 00 AL FLA4PH 6 3 Phase Black 4 5 3 2823085 00 2823085 00 3 AL FLA4PE 6 3 PE Green yellow 4...

Страница 31: ...no 1 m ID no 5 m Al RKLA2 5PH M5 Phase Black 2 5 4 5 2808971 00 2808971 00 5 Al RKLA2 5PE M5 PE Green yellow 2 5 3 9 2808958 00 2808958 00 5 Al RKLA4PH M5 HL Phase Black 4 5 3 2821809 00 2821809 00 5...

Страница 32: ...0 5 Al RKLA4PH M6 HL Phase Black 4 5 3 2808751 00 2808751 00 5 Al RKLA4PE M6 PE Green yellow 4 4 9 2808752 00 2808752 00 5 Al RKLA6PH M6 Phase Black 6 6 5 2808745 00 2808745 00 5 Al RKLA6PE M6 HL PE G...

Страница 33: ...0171817 00 Weight kg 0 142 Delivery without profile Equipotential bonding from VCL profile to VMT pro file Rail section with PE grounding VCL2 40F 1000HSCP 0281547 00 VCL2 100C 1000HSCP 0281548 00 Eq...

Страница 34: ...4000SSD 0281604 00 Weight 100C 4m kg 3 522 Weight 40F 4m kg 3 300 Delivery length mm 4000 Hanger spacing mm 800 Segment Section Phase PE VCL3 100C 4000HSC 0281594 00 VCL3 100C 3000HSC 0281593 00 VCL3...

Страница 35: ...End segment Phase ESM VCL3 100C SSD 0281578 00 ESM VCL3 40F SSD 0281585 00 Weight 1m kg 0 662 Delivery length mm 1000 Segment Section Phase PE ESM VCL3 100C HSC R 0281579 00 ESM VCL3 100C HSC L 028158...

Страница 36: ...A 50 Expansion section Phase PE DT DVCL3 100C HSC 0281600 00 DT DVCL3 40F HSC 0281606 00 Weight kg 0 953 Delivery length mm 1000 Max current A 50 Line feed Phase ES VCL2 100C SSD 50A 0281502 00 ES VCL...

Страница 37: ...ight kg 0 020 Current collector DEAS SA DEAS 2 30 2 SS 3 5 0 2 2 PA for controller 0281610 00 SA_DEAS 2 30 2 HS 3 5 0 2 2 PA for main power with PE 0281615 00 Weight kg 0 4 Number of poles 3 Phase spa...

Страница 38: ...E for control current 0281616 00 SA EASL 20 3 HS 0 2 2 PA V E for main current with PE 0281617 00 Weight kg 0 12 Number of poles 3 Phase spacing mm 15 Max current A 20 Tolerance X direction mm 15 Tol...

Страница 39: ...with VMT PASK current collector Ident No SA PASK 50 3L HS 3 4 0281633 00 SA PASK 50 3R HS 3 4 0281634 00 SA PASK 50 4L HS 4 4 0281624 00 SA PASK 50 4R HS 4 4 0281627 00 SA PASK 50 5L HS 5 6 0281625 00...

Страница 40: ...5PH 6 3 Phase Black 2 5 4 5 2809171 00 2809173 00 AL FLA2 5PE 6 3 PE Green yellow 2 5 3 9 2809175 00 2809177 00 AL FLA4PH 6 3 Phase Black 4 5 3 2823085 00 2823085 00 3 AL FLA4PE 6 3 PE Green yellow 4...

Страница 41: ...6PE M4 PE Green yellow 6 6 3 2808738 00 2808738 00 3 RKLA for M5 type Pin Color Cable cross section mm2 Outer diam eter mm ID no 1 m ID no 5 m Al RKLA2 5PH M5 Phase Black 2 5 4 5 2808971 00 2808971 00...

Страница 42: ...0 5 Al RKLA4PH M6 HL Phase Black 4 5 3 2808751 00 2808751 00 5 Al RKLA4PE M6 PE Green yellow 4 4 9 2808752 00 2808752 00 5 Al RKLA6PH M6 Phase Black 6 6 5 2808745 00 2808745 00 5 Al RKLA6PE M6 HL PE G...

Страница 43: ...0171817 00 Weight kg 0 142 Delivery without profile Equipotential bonding from VCL profile to VMT pro file Rail section with PE grounding VCL3 40F 1000HSCP 0281638 00 VCL3 100C 1000HSCP 0281637 00 Eq...

Страница 44: ...f other applications e g in crane technology Displacement and positioning systems can of course also be used in parallel A further plus for the user are the large hanger dis tances which enable quick...

Страница 45: ...ixpoint Profile VMT 6000 0171546 01 Weight kg 12 336 Delivery length mm 6000 Terminal connector KV VMT 0171536 00 Weight kg 0 845 Compact holder Weight kg Ident No KH VCL4 VMT 0 385 0171818 00 KH VCL5...

Страница 46: ...sole for auxiliary sup port HST 15 1 062 0171539 00 3 VMT S Screw console 15 0 902 0171547 00 4 VMT 55 125 Clamping console 15 55 to 65 65 to 75 75 to 85 85 to 95 95 to 105 105 to 115 115 to 125 1 600...

Страница 47: ...HSE 450 450 0781694 00 HRL HSE 500 500 0781677 00 Type Height mm Ident No HRL HST 50 250 250 0157172 00 HRL HST 50 300 300 0152804 00 HRL HST 50 350 350 0156393 00 HRL HST 50 400 400 0152661 00 HRL H...

Страница 48: ...nauthorized persons who do not meet the requirements described here do not know the dangers in the respective work area Keep unauthorized persons away from the work area If in doubt speak to people an...

Страница 49: ...ctly observed during assembly Appropriate handling of materials Clean and metallic bright surfaces on all contact points Smooth crossovers free of burrs of the conductor rail profiles at the ends in o...

Страница 50: ...uctor rail adjustable torque wrench for 1 4 Nm 5 Nm 7 Nm and 15 Nm reversible ratchet with an extension and nut with SW 7 200 mm steel rule Allen wrench size 4 soft face hammer head about 50 mm dia Sc...

Страница 51: ...kplace Required tools Drill 4 5 mm Assembly instructions 1 Determine position for the bore hole and fix in position 2 Drill hole with 4 5 mm dia Drill out mounting holes for holder Arrangement example...

Страница 52: ...ment without fixpoint Assembly instructions Requirements Clean and tidy workplace Required tools Drill bit according to table below 4 6 mm 4 9 mm Assembly instructions 1 Determine position for the bor...

Страница 53: ...Drilling template for VCL in VMT Ident No 0171840 00 Weight kg 0 109 Assembly safety device Ident No 0281526 Weight kg 0 050 Mounting handle for feed terminal VCL MZ MH ES VCL 10027863 Weight kg 0 09...

Страница 54: ...14 File FSF Ident No 2812964 Weight kg 0 085 Component Length mm Conductor system segment 4000 End segment start 1000 End segment end 1000 Component Length mm Line feed 1000 Expansion joint 1000 Possi...

Страница 55: ...5 26 106018 90 2 26 27 110019 60 2 27 28 114020 30 2 28 29 118021 00 2 29 30 122021 70 2 30 31 126022 40 2 31 32 130023 10 2 32 33 134023 80 2 33 34 138024 50 2 34 35 142025 20 2 35 36 146025 90 2 36...

Страница 56: ...nt the hangers to the carrier using suitable expanding rivets 2 Use the plastic hammer for fixing Step 3 Assembly instructions 1 Connect the screw terminal with the feed cable DANGER Danger of life du...

Страница 57: ...a risk of crushing of the ex tremities between the individual components Take care of your extremities Wear personal protective equipment see Chap ter 2 Step 6 Assembly instructions 1 Mount the end s...

Страница 58: ...amp to relieve the fixpoint during connector installation 5 3 4 Transfer guides NOTICE One of the two transfer guides must be mounted as a fixpoint The transfer guides may only have an air gap of betw...

Страница 59: ...il joint with the mounting handle and a plastic ham mer CAUTION The connector is not reusable If assembly is unsuc cessful or the connection is faulty please proceed as described in Chapter 5 3 6 Step...

Страница 60: ...hed the penul timate 4 meter section Determine the exact length to the end point and adapt the last sections accordingly 5 3 6 Renewing conductor rail joints Assembly disassembly steps Cutting tool De...

Страница 61: ...the connectors and connecting cap on the last section 2 Clip the end segment into the hanger and connect the section 3 Insert the screw terminals in both conductor rail ends and push the transfer guid...

Страница 62: ...Clean and tidy workplace Required tools Tape measure Handsaw chop saw File Assembly steps 1 Pull the copper profile out of the insulating housing for exactly 15 mm and make sure that the copper is fl...

Страница 63: ...x 4 N per carbon brush The current collector must be able to move freely Connecting cables may not restrict or impede movement Double current collector assembly DEAS Assembly instructions Prerequisite...

Страница 64: ...sys tem phase center off NOTICE Installation dimension 80 mm Number of poles 3 6 Phase spacing 15 mm Max current 50 A Tolerance X direction 15 mm Tolerance Y direction 20 mm Contact pressure approx 4...

Страница 65: ...trans fer guide In special cases a fixpoint can also be realized using a hanger On the back of the conductor line each hanger has two recesses for fixing CAUTION This type of fixpoint may only be use...

Страница 66: ...th help of the drilling device drill through the insulating housing and the back of the conductor line 3 Press the fixpoint clamps into the previously drilled holes and align them with the recesses of...

Страница 67: ...Requirements Clean and tidy workplace Assembly steps 1 Before installing the expansion joint in the line press the mounting clip into the expansion gap 2 Mount the expansion joint in the intended line...

Страница 68: ...r in tension unauthorized approxima tion CAUTION Danger of crushing between the individual components During assembly there is a risk of crushing of the extremities between the individual components T...

Страница 69: ...tep 2 Assembly instructions 1 Pull the two conductor system parts apart and re move the connection terminals Step 3 Assembly instructions 1 Connect the connection terminals to the screw terminals At t...

Страница 70: ...m behind over a joint connector 2 Now screw the hexagon socket screws to the cor responding connection terminal with 7 Nm transfer guide M5 feed terminal M6 The mounting handle prevents twisting durin...

Страница 71: ...g 2 570 Installation pliers Ident No 0171533 00 Weight kg 0 700 Drilling template for fixpoint terminal MZ BS AH VCL2 0281525 MZ BS AH VCL3 0281608 Weight kg 0 050 Drilling template for VCL in VMT MZ...

Страница 72: ...15 0 882 0171839 00 2 VMT SPW Clamping console for auxiliary sup port HST 15 1 062 0171539 00 3 VMT S Screw console 15 0 902 0171547 00 4 VMT 55 125 Clamping console 15 55 to 65 65 to 75 75 to 85 85 t...

Страница 73: ...aces of less than 2 meters the alternate fixing of the hangers is not required NOTICE Please observe the following torques regarding the different hangers The AV VMT BS hangers are fixated with drill...

Страница 74: ...cted type Tighten the M10 screws to a torque of 15 Nm Ensure that the clamping springs always face upwards For other clamping springs please use the torques specified in the table above Step 2 Assembl...

Страница 75: ...pment see Chap ter 2 Step 4 Assembly instructions 1 Attach the connection sections and lock them us ing the installation pliers as shown in Step 3 NOTICE Install the VMT sections with a max air gap of...

Страница 76: ...VMT shorter lengths Step 6 Required tools Sawing device SV VMT Assembly instructions 1 If required you can create shorter lengths on the construction side using the SV VMT sawing de vice 2 Deburr the...

Страница 77: ...tor is essential See IEC 60364 4 41 Step 1 Required tools Wrench Assembly instructions 1 Screw the equipotential bonding cable 4 3 12 Equipotential bonding or 4 4 12 as shown to a point on the VMT pro...

Страница 78: ...TION Danger of crushing between the individual components During assembly there is a risk of crushing of the extremities between the individual components Take care of your extremities Wear personal p...

Страница 79: ...the exact position of the feed terminal on the supplied system plan The feed terminal must have a distance of 200 mm from the hanger on the side to which the connecting cables are led away 2 Make two...

Страница 80: ...d dimension 100 mm NOTICE Observe the hanger distances from the supplied sys tem or installation plan Step 2 Required tools Assembly safety device Assembly instructions 1 Click the first section into...

Страница 81: ...e sure that the lugs of the holders are properly snapped in place see figure below 2 For other transfer guides proceed as described in step 2 NOTICE The profile connectors should be mounted outside th...

Страница 82: ...parts or situations after assembly and issue and sign an acceptance certificate Check the general functionality of the system Clearances of the line transitions and transfers Open spaces and interfer...

Страница 83: ...on 6 2 Conduct in case of malfunction General principle If case of malfunctions that present an immediate hazard to persons or property immediately activate the safety devices Determine the cause of t...

Страница 84: ...ing instructions must be observed DANGER Danger of life due to electrical current Contact with live parts can result in life threating injuries Make sure that the components are not live or in tension...

Страница 85: ...sons cannot assess the risks involved in operating the sys tem and expose themselves and others to the risk of serious or fatal injuries Have all work performed only by persons qualified for the task...

Страница 86: ...placement head 0 5 0 016 2808580 00 SK EK DEAS 2 30 PE 36 6 3 H Rear replacement head 0 5 0 016 2808581 00 SK EK DEAS 2 30 PH 36 6 3 V Front replacement head 0 5 0 016 2808575 00 SK EK DEAS 2 30 PE 36...

Страница 87: ...ductor rails and of burn marks Replace damaged burnt parts In particular remove accumulated car bon brush dust at separating points and transfer guides using a hand brush Remove any small burns or di...

Страница 88: ...joints bearings and hinge pins Inspection for mechanical damage of any type Electrical checks Check for wear of graphite contacts firm seat of all contact screws and cable attachments Clean oxidized...

Страница 89: ...lass H filter Retrofitting a HEPA filter is required Do not eat drink or smoke during work Dust in the vacuum cleaner bag or the air filter can be disposed of as commercial waste in the usual quantiti...

Страница 90: ...sport damage upon receipt If any external damage is found Refuse delivery or accept delivery only conditionally Note the scope of the damage in the transport documents or on the carrier s delivery not...

Страница 91: ...WARNING Risk of death from improper replacement or removal Errors during the removal or replacement of components may cause life threatening situations or significant property damage Observe the safe...

Страница 92: ...CTRIFICATION SYSTEMS VCL2 Series VCL3 Series Have been investigated by UL in accordance with the Standard s indicated on this Certificate Standard s for Safety UL508 CSA C22 2 NO 14 18 Industrial Cont...

Страница 93: ...cified hereafter conform to the relevant EU regulations This declaration will be void when amendments not approved by us will be made to the products Compact coonductor system Paul Vahle GmbH Co KG Po...

Страница 94: ...ls 19 G Grounding and short circuiting 8 H Hangers 18 I Information to the instructions 3 Isolation 9 M measuring equipment 48 O Operating company 9 Operation 47 Owner obligations 9 Q Qualifications 1...

Страница 95: ...INDEX 93 U Unloading 88...

Страница 96: ...CE Technical Documentation...

Отзывы: