Maintenance and service
94
27.06.2011
ver. 2
5.3
Seed feed housing and rape brush
The inside of the seed feed housing
must be cleaned out regularly and frequent checks must be
made for signs of wear on plastic and rubber components. It is specially important to ensure that
seed additive deposits do not build up in the scoops, reducing their volume.
The casing with the scale can be drained from below and can be rinsed through once the feed hous-
ing has been turned down nearly to zero.
Clean inside the transparent transmission cover when necessary.
Check that the blades of the cellwheel do not jam but that they bear against the bottom of the
groove during setting from zero and upwards.
Check the wiring.
Rape brush
Before setting the drill for rapeseed, always check the rape brush and clean it if necessary. Check
that the brush spin easily on it's axle. The rape brush must never be greased.
5.4
Locking device
Figure 5.9
Do not lubricate the locking device. Regularly inspect the device for correct operation. The lock-
ing hooks (A) on the rear of the seed hopper should connect with the lugs (B) on the side sections.
Grease the locking device regularly. Use grease on the angled surface of the locking bar and
around where the bar is in contact with the hopper.
Figure 5.7
Figure 5.8
A
B
Содержание Rapid RDA 400S
Страница 2: ...2 27 06 2011 ver 2 ...
Страница 4: ...4 ...
Страница 16: ...Safety regulations 16 27 06 2011 ver 2 ...
Страница 28: ...Instructions and settings 28 27 06 2011 ver 2 3 8 Horizontal alignment Figure 3 22 C B A ...
Страница 89: ...RDA 400S 27 06 2011 ver 2 89 ...
Страница 91: ...RDA 400S 27 06 2011 ver 2 91 Figure 5 4 ...
Страница 97: ...RDA 400S 27 06 2011 ver 2 97 ...
Страница 136: ...Appendices 136 27 06 2011 ver 2 ...
Страница 137: ......