RDA 400-450 S
Ver.3 29.06.2007
93
clutch should then stop the feed roller. If the alarm is
generated although the LED lights, a likely cause is a
defective magnetic clutch.
28 Workstation not connected.
- Check whether the intermediate cable between the
Control Station and Workstation is connected. Inspect
the condition of the cable and connectors. The green
indicator lamp on the Workstation shows that voltage
is present, however, the lamp could light even though
the intermediate cable is partially damaged.
29 Voltage error Workstation 1.
- Workstation 1 receives a lower voltage than 11 V. In-
spect the connections and connectors of the interme-
diate cable. The function of the hydraulic valves, etc.
may cease to work.
30 Voltage error Workstation 2.
- Workstation 2 receives a lower voltage than 11 V. In-
spect the connections and connectors of the interme-
diate cable. The function of the hydraulic valves, etc.
may cease to work.
31 Seed level guard.
- Check the cable, connectors and connections of the
sensor.
- Check that the sensor is not dirty or damp. Dry the
sensor with a dry cloth.
- The sensor may be defective.
39 Speed sensor.
- Check the rpm sensor of the drive wheel transmission.
- Check the cable, connector and connection of the sen-
sor.
41 Hydraulic motor, seed out-
put.
- Is the hydraulic oil flow sufficient? Does the seed out-
put fan start?
- Check whether the seed boxes can rotate by hand.
- Check the cable, connector and connection of the sen-
sor.
- Check the operation of the sensor.
- Check whether the electric valve in the fan unit re-
ceives power.
Содержание Rapid RDA 400S
Страница 1: ...Ver 3 29 06 2007 900234 en Instructions Seed drill RAPID series RDA 400 450 S No 12 800 14 799...
Страница 2: ...2 Ver 3 29 06 2007...
Страница 18: ...Instructions and settings 18 Ver 3 29 06 2007 2 7 Horizontal alignment Figure 2 18 A E C D B...
Страница 39: ...RDA 400 450 S Ver 3 29 06 2007 39...
Страница 69: ...RDA 400 450 S Ver 3 29 06 2007 69 Figure 4 4...
Страница 109: ......