RDA 400-450 S
Ver.3 29.06.2007
91
5.3
Alarm list
1 Low seed level.
- Check the seed level of the seed hopper.
If there is seed in the seed hopper:
- The sensitivity of the sensor has been incorrectly set.
5 The seed output device does
not rotate.
If the seed box does not move:
- Check whether the transmission between the drive
wheel and the seed box is intact.
If the alarm is generated even
though the seed box rotates:
- Check which alarm time has been programmed.
- Check the cables, connectors and connections.
- Check the operation of the sensor. The LED of the
sensor should light when the toothed plate passes. The
distance between the sensor and the toothed plate
should be 1 - 2 mm. Adjust if necessary.
A lit LED, however, is not necessarily any guarantee
that the sensor is operating.
- Check the condition and mounting of the toothed
plate.
13 Tramlining.
- The alarm is generated if tramlining does not take
place when the Control Station outputs a tramline sig-
nal or if tramlining takes place when the Control Sta-
tion does not output a tramline signal.
- Check the function of the tramline components in the
distributor head: motor, turn plate, springs and doors.
Clean if necessary.
- Check the cable, connector and connection of the sen-
sor.
- Check the sensor.
Содержание Rapid RDA 400S
Страница 1: ...Ver 3 29 06 2007 900234 en Instructions Seed drill RAPID series RDA 400 450 S No 12 800 14 799...
Страница 2: ...2 Ver 3 29 06 2007...
Страница 18: ...Instructions and settings 18 Ver 3 29 06 2007 2 7 Horizontal alignment Figure 2 18 A E C D B...
Страница 39: ...RDA 400 450 S Ver 3 29 06 2007 39...
Страница 69: ...RDA 400 450 S Ver 3 29 06 2007 69 Figure 4 4...
Страница 109: ......