RDA 400-450 S
Ver.3 29.06.2007
89
- Check whether the tooth wheel in the seed box is dam-
aged.
- Check whether the inductive detector is sufficiently
close to the rotating tooth wheel. Adjust if necessary.
The area meter/speedometer
has no indication or an incorrect
indication!
Mechanical output:
- Does the sensor receive a signal from the drive wheel
shaft sensor under the chain guard? Disassemble the
guard and inspect the sensor. See ”
- Check the cable, connector and connection of the sen-
sor.
- Has the Control Station been programmed with the
correct drive wheel circumference (usually 240 cm)?
See
”2.21.3 Programming” on page 47.
Increase the value in case of too small an area or too
low a speed.
Decrease the value in case of too large an area or too
high a speed.
Hydraulic output:
- Has the Control Station been programmed with the
correct number of pulses per metre? See ”
.
If the value in the area/speed field is too low, then re-
duce the number of pulses per metre.
If the value in the area/speed field is too high, then in-
crease the number of pulses per metre.
The tramline doors seize!
- Are the doors blocked or wedged up due to seed or
rubbish?
In this case dismantle the glass cover on the distribu-
tor head and clean.
The drilling depth of the centre
and side section differs!
- Check whether the long ram rod of the folding ram is
completely extended and that the rod does not slowly
retract during driving.
- Check the setting on the wing sections, see
justing the wing sections” on page 20.
- Check the adjustment of the cranks on the wing sec-
Содержание Rapid RDA 400S
Страница 1: ...Ver 3 29 06 2007 900234 en Instructions Seed drill RAPID series RDA 400 450 S No 12 800 14 799...
Страница 2: ...2 Ver 3 29 06 2007...
Страница 18: ...Instructions and settings 18 Ver 3 29 06 2007 2 7 Horizontal alignment Figure 2 18 A E C D B...
Страница 39: ...RDA 400 450 S Ver 3 29 06 2007 39...
Страница 69: ...RDA 400 450 S Ver 3 29 06 2007 69 Figure 4 4...
Страница 109: ......