Appendices
102
Ver.3 29.06.2007
6.4.2
Level guards; capacitive sensors
Figure 6.5
6.4.3
Rotation guards; inductive sensors
Figure 6.6
Table 6.4
Workstation
connection
Ter-
minal
(A)
Cable
colour
Ter-
minal
(B)
Function
Matter
detected
Matter not
detected
WS1-1
1
Black
1
Matter detected = Soil, LED lights Max. 1 V
Min. 8 V
2
White
2
Matter not detected = Soil
Min. 8 V
Max. 1 V
3
Brown
3
12 V
4
Blue
4
0 V
Table 6.5
Workstation
connection
Ter-
minal
(A)
Cable
col-
our
Ter-
minal
(B)
Function
Metal
detected
Metal not
detected
WS1-4
WS1-5
WS1-25
1
Black
1
Metal detected = Soil, diode lights Max. 1 V
Min. 8 V
2
3
Brown 2
12 V
4
Blue
3
0 V
A
B
A
B
Содержание Rapid RDA 400S