Place the VACON
®
20 CP on the appropriate heatsink area and tighten the screws as listed in
the following table:
Figure 12. Heatsink plate for MS2 (upper view).The thickness of the plate is 6.0 mm (0.24
in).
Frame size
Screw size
Tightening torque N•m
(lb•in)
MS2
M5 (according to DIN
7985 - 8.8
(with washer))
2.0 to 2.5 Nm
(17.70 to 22.13 lbf•in)
MS3
M5 (according to DIN
7985 - 8.8
(with washer))
2.0 to 2.5 Nm
(17.70 to 22.13 lbf•in)
Table 6. Screw size and tightening torque.
Tighten all screws according to specified torques. Failure to do so, may inhibit
drive cooling and cause possible damage to the drive.
Frame
Dimensions W x H x D
[mm]
[in]
MS2
64.0 x 110.0 x 6.0
2.52 x 4.33 x 0.24