8
vacon • 81
Options
8.4.2
Resetting fault
When a fault appears and the drive stops examine the cause of the fault, perform the action advised
in the Fault Tracing paragraph and reset the fault by pressing the RESET button.
8.4.3
Local/Remote control button
The LOC/REM button is used for two functions: to quickly access the Control page and to easily
change between the Local (Keypad) and Remote control places.
Control places
The
control place
is the source of control where the drive can be started and stopped. Every control
place has its own parameter for selecting the frequency reference source. In the VACON
®
20 CP
drive, the
Local control place
is always the keypad. The
Remote control place
is determined by pa-
rameter (I/O or Fieldbus). The selected control place can be seen on the status bar of the keypad.
Remote control place
I/O and Fieldbus can be used as remote control places.
Local control
Keypad is always used as control place while in local control. Local control has higher priority than
remote control. Switching between Local and Remote Control can be done by pressing the LOC/
REM-button on the keypad.
Содержание 20 CP
Страница 1: ...vacon 20 cp ac drives installation Technical and Maintenance manual ...
Страница 2: ......
Страница 6: ...vacon 3 ...
Страница 16: ...1 vacon 13 Safety Figure 6 STO certificate ...
Страница 18: ...1 vacon 15 Safety ...
Страница 24: ...vacon 21 Receipt of delivery 2 ...
Страница 36: ...3 vacon 33 Mounting ...
Страница 48: ...4 vacon 45 Power cabling ...
Страница 64: ...5 vacon 61 Control unit ...
Страница 111: ...Safe Torque Off vacon 108 Service support find your nearest Vacon service center at www vacon com 9 ...