Parameter description
vacon • 48
Service support: find your nearest Vacon service center at www.vacon.com
4
4.3
Analogue inputs
P3.1 AI1
SIGNAL
RANGE
P3.5 AI2
SIGNAL
RANGE
Range of the electrical signal.
0: 0-100%: 0…10V or 0… 20mA
1: 20-100%: 2…10V or 4… 20mA
P3.4 AI1
FILTER
TIME
P3.8 AI2
FILTER
TIME
Low pass filter time constant, to reduce noise. When this parameter is given a value greater
than 0 the function that filters out disturbances from the incoming analogue signal is activated.
NOTE: Long filtering time makes the regulation response slower!
Figure 7.AI1 signal filtering.
P3.2 AI1
CUSTOM
MIN
P3.6 AI2
CUSTOM
MIN
Customized value for minimum signal. Effective when different than 0%
P3.3 AI1
CUSTOM
MAX
P3.7 AI2
CUSTOM
MAX
Customized value for maximum signal. Effective when different than 100%.
%
100%
63%
P3.2
t
Filtered signal
Unfiltered signal