vacon • 31
Description of Groups
3
3.3.10
Group Autoreset: Menu PAR G10
Code
Parameter
Min
Max
Unit
Default
ID
Description
P10.1
Automatic fault reset
0
1
0
731
0 = Disabled
1 = Enabled
P10.2
Wait time
0.10
10.0
m
1.0
717
Wait time before the first
reset is executed.
P10.3
Automatic reset tries
1
10
5
759
NOTE: Total number of trials
(irrespective of fault type)
P10.4
Underload reset Time
1
0.1
1200.0
m
2.0
1927
P10.5
Underload reset Time
2
0.1
1200.0
m
30.0
1928
P10.6
Underload reset Time
3
0.1
1200.0
m
300.0
1929
P10.7
Underload Tries T1,T2
1
10
2
1930
Table 16. Autoreset group.
NOTE!
Visibility of the group depends on P1.16.
Содержание 20 CP/X
Страница 1: ...vacon 20 cp x ac drives Solar pump application manual ...
Страница 2: ......
Страница 4: ...vacon 1 5 Fault tracing 82 ...
Страница 6: ...1 vacon 3 Safety ...
Страница 16: ...vacon 13 Solar pump Application 2 ...
Страница 90: ......
Страница 91: ......