Description of Groups
vacon • 26
Service support: find your nearest Vacon service center at www.vacon.com
3
3.3.7
Group Supervisions: Menu PAR G7
Code
Parameter
Min
Max
Unit
Default
ID
Description
P7.1
Frequency
supervision 1
0
2
0
315
0 = not used
1 = Low limit
2 = High limit
P7.2
Frequency supervision
value 1
0.00
P1.2
Hz
0.00
316
Output frequency supervision
threshold value
P7.3
Current supervision
value
0.00
2 x I
H
A
0.00
1811
Current supervision thresh-
old value
P7.4
AnalogIn Supv Signal
0
1
0
356
0 = AI1
1 = AI2
P7.5
AnalogIn Supv ON level
0.00
100.00
%
80.00
357
ON threshold AI supervision
P7.6
AnalogIn Supv OFF
level
0.00
100.00
%
40.00
358
OFF threshold AI supervision
P7.10
Process Source Select
0
5
2
1036
Selection of variable propor-
tional to process:
0 = PID feedback value
1 = Output frequency
2 = Motor speed
3 = Motor torque
4 = Motor power
5 = Motor current
P7.11
Process Val
Decim Digits
0
3
1
1035
Decimals on process display
variable
P7.12
Process Max Value
0.0
3276.7
100.0
1034
Process display max value (it
depends on P7.11: with zero
decimal digit the max value
is 32767; with 1 decimal digit
the max value is 3276.7)
Table 13. Supervisions group.
NOTE!
Visibility of the G6 and G7 groups depends on P1.16.
Содержание 20 CP/X
Страница 1: ...vacon 20 cp x ac drives Solar pump application manual ...
Страница 2: ......
Страница 4: ...vacon 1 5 Fault tracing 82 ...
Страница 6: ...1 vacon 3 Safety ...
Страница 16: ...vacon 13 Solar pump Application 2 ...
Страница 90: ......
Страница 91: ......