Monitoring Menu
vacon • 58
Service support: find your nearest Vacon service center at www.vacon.com
5
Table 34. Trend curve parameters
Code
Parameter
Min
Max
Unit
Default
ID
Description
M2.2.1
View Trend curve
Enter this menu to select and
monitor values for viewing in
curve form.
P2.2.2
Sampling interval
100
432000
ms
100
2368
Set here the sampling inter-
val.
P2.2.3
Channel 1 min
-214748
1000
-1000
2369
Used by default for scaling.
Adjustments might be neces-
sary.
P2.2.4
Channel 1 max
-1000
214748
1000
2370
Used by default for scaling.
Adjustments might be neces-
sary.
P2.2.5
Channel 2 min
-214748
1000
-1000
2371
Used by default for scaling.
Adjustments might be neces-
sary.
P2.2.6
Channel 2 max
-1000
214748
1000
2372
Used by default for scaling.
Adjustments might be neces-
sary.
P2.2.7
Autoscale
0
1
0
2373
The selected signal is auto-
matically scaled between
min and max values if this
parameter is given value 1.
9251.
e
m
f
OK
Содержание 100X series
Страница 1: ...vacon 100 x ac drives Solar pump application manual ...
Страница 2: ......
Страница 6: ...vacon 3 Vacon 100X Solar Pump Application 1 ...
Страница 8: ...2 vacon 5 Safety ...
Страница 59: ...User Interfaces vacon 56 Service support find your nearest Vacon service center at www vacon com 4 ...
Страница 160: ...vacon 157 Parameters 6 ...
Страница 169: ...Fault vacon 166 Service support find your nearest Vacon service center at www vacon com 7 ...
Страница 170: ...7 vacon 167 Fault ...
Страница 171: ......