User Interfaces
vacon • 32
Service support: find your nearest Vacon service center at www.vacon.com
4
4.1.5.2
Using the text keypad
Editing values
Change value of a parameter following the procedure below:
1.
Locate the parameter.
2.
Enter the Edit mode by pressing OK.
3.
Set new value with the arrow buttons up/down. You can also move from digit to digit with
the arrow buttons left/right if the value is numerical and change then the value with the
arrow buttons up/down.
4.
Confirm change with OK button or ignore change by returning to previous level with Back/
Reset button.
Figure 11. Editing values
Resetting fault
Instructions for how to reset a fault can be found in chapter 7 on page 158.
Function button
The FUNCT button is used for four functions:
Control places
The
control place
is the source of control where the drive can be started and stopped. Every
control place has its own parameter for selecting the frequency reference source. The
Local
control place
is always the keypad. The
Remote control place
is determined by parameter
P3.2.1 (I/O or Fieldbus). The selected control place can be seen on the status bar of the keypad.
Remote control place
I/O A, I/O B and Fieldbus can be used as remote control places. I/O A and Fieldbus have the
lowest priority and can be chosen with parameter P3.2.1
(Rem Control Place)
. I/O B, again,
can bypass the remote control place selected with parameter P3.2.1 using a digital input. The
digital input is selected with parameter P3.5.1.7
(I/O B Ctrl Force)
.
Local control
Keypad is always used as control place while in local control. Local control has higher priority
than remote control. Therefore, if, for example, bypassed by parameter P3.5.1.7 through digi-
tal input while in
Remote
, the control place will still switch to Keypad if
Local
is selected.
Switching between Local and Remote Control can be done by pressing the FUNCT-button on
the keypad or by using the "Local/Remote" (ID211) parameter.
OK
OK
OK
BACK
RESET
9168.emf
Содержание 100X series
Страница 1: ...vacon 100 x ac drives Solar pump application manual ...
Страница 2: ......
Страница 6: ...vacon 3 Vacon 100X Solar Pump Application 1 ...
Страница 8: ...2 vacon 5 Safety ...
Страница 59: ...User Interfaces vacon 56 Service support find your nearest Vacon service center at www vacon com 4 ...
Страница 160: ...vacon 157 Parameters 6 ...
Страница 169: ...Fault vacon 166 Service support find your nearest Vacon service center at www vacon com 7 ...
Страница 170: ...7 vacon 167 Fault ...
Страница 171: ......