3
vacon • 21
Startup
P1.35.10
U/f Mid Voltg
0.0
100.0
%
100.0
605
Provided that the program-
mable U/f curve has been
selected (par. P3.1.4.1), this
parameter defines the mid-
dle point voltage of the
curve.
P1.35.11
Zero Freq Voltg
0.00
40.00
%
Varies
606
This parameter defines the
zero frequency voltage of the
U/f curve. The default value
varies according to unit size.
P1.35.12
StartMagnCurrent
0.00
Varies
A
Varies
517
Defines the DC current fed
into motor at start. Disabled
if set to 0.
P1.35.13
StartMagnTime
0,00
600,00
s
0,00
516
This parameter defines the
time for how long DC cur-
rent is fed to motor before
acceleration starts.
P1.35.14
DC Brake Current
Varies
Varies
A
Varies
507
Defines the current injected
into the motor during DC-
braking.
0 = Disabled
P1.35.15
DC BrakeTime
0,00
600,00
s
0,00
508
Determines if braking is ON
or OFF and the braking time
of the DC-brake when the
motor is stopping.
P1.35.16
DC Start Freq
0,10
10,00
Hz
1,50
515
The output frequency at
which the DC-braking is
applied.
P1.35.17
Load drooping
0.00
50.00
%
0.00
620
The drooping function
enables speed drop as a
function of load. Drooping
will be defined in percent of
nominal speed at nominal
load.
P1.35.18
Load drooping time
0.00
2.00
s
0.00
656
Load drooping is used in
order to achieve a dynamic
speed drooping because of
changing load. This parame-
ter defines the time during
which the speed is restored
to the level it was before the
load increase.
P1.35.19
Load drooping mode
0
1
0
1534
0 = Normal; Load drooping
factor is constant through
the whole frequency range
1 = Linear removal; Load
drooping is removed lin-
early from nominal fre-
quency to zero frequency
Table 6. Multi-purpose start-up wizard menu
Содержание 100X series
Страница 1: ...vacon 100 x ac drives Solar pump application manual ...
Страница 2: ......
Страница 6: ...vacon 3 Vacon 100X Solar Pump Application 1 ...
Страница 8: ...2 vacon 5 Safety ...
Страница 59: ...User Interfaces vacon 56 Service support find your nearest Vacon service center at www vacon com 4 ...
Страница 160: ...vacon 157 Parameters 6 ...
Страница 169: ...Fault vacon 166 Service support find your nearest Vacon service center at www vacon com 7 ...
Страница 170: ...7 vacon 167 Fault ...
Страница 171: ......