Parameters
vacon • 130
Service support: find your nearest Vacon service center at www.vacon.com
6
6.2.10
Analog inputs
AI1 F
ILTER
T
IME
When this parameter is given a value greater than 0 the function that filters out disturbances
from the incoming analogue signal is activated.
NOTE: Long filtering time makes the regulation response slower!
Figure 35. AI1 signal filtering
AI1 S
IGNAL
R
ANGE
The signal range for the analogue signal can be selected as:
Type of the analogue input signal (current or voltage) is selected by the dip switches on the con-
trol board (see Installation manual).
In the following examples, the analogue input signal is used as a frequency reference. The fig-
ures show how the scaling of the analogue input signal is changed depending on the setting of
this parameter.
Selection
number
Selection name
Description
0
0…10 V/0…20 mA
Analogue input signal range 0…10V or
0…20mA (depending on dip switch settings on
the control board). Input signal used 0…100 %.
[%]
100%
63%
ID378
t [s]
9095.emf
Filtered signal
Unfiltered signal
Analogue input
signal
Содержание 100X series
Страница 1: ...vacon 100 x ac drives Solar pump application manual ...
Страница 2: ......
Страница 6: ...vacon 3 Vacon 100X Solar Pump Application 1 ...
Страница 8: ...2 vacon 5 Safety ...
Страница 59: ...User Interfaces vacon 56 Service support find your nearest Vacon service center at www vacon com 4 ...
Страница 160: ...vacon 157 Parameters 6 ...
Страница 169: ...Fault vacon 166 Service support find your nearest Vacon service center at www vacon com 7 ...
Страница 170: ...7 vacon 167 Fault ...
Страница 171: ......