Figure 9.4: Start/Stop logic, selection 1
Selection
number
Selection name
Note
1
CS1:Forward(edge)
CS2:Inverted stop
Explanations
1
Control signal (CS) 1 actives causing the
output frequency to rise. The motor runs
forward.
6
CS1 activates and the motor accelerates
(FWD) towards the set frequency
because the Run enable signal has been
set to TRUE.
2
CS2 inactivates causing the frequency to
drop to 0.
7
Keypad stop button is pressed and the
frequency fed to the motor drops to 0.
3
CS1 inactivates causing the output fre-
quency to rise again. The motor runs
forward.
8
CS1 activates causing the output fre-
quency to rise again. The motor runs
forward.
4
Run enable signal is set to FALSE, which
drops the frequency to 0. The run enable
signal is configured with par. 5.7.
9
CS2 inactivates causing the frequency to
drop to 0.
5
Start attempt with CS1 is not successful
because Run enable signal is still
FALSE.
Содержание 10
Страница 1: ......
Страница 17: ...14 vacon installation Tel 358 0 201 2121 Fax 358 0 201 212205 3 MI1 MI3 3P 230 V POWER LOSS ...
Страница 18: ...installation vacon 15 24 hour support 0 201 212 575 Email vacon vacon com 3 ...
Страница 19: ...16 vacon installation Tel 358 0 201 2121 Fax 358 0 201 212205 3 MI1 MI3 1P 230 V POWER LOSS ...
Страница 20: ...installation vacon 17 24 hour support 0 201 212 575 Email vacon vacon com 3 ...